Jaipur
+918529833535

'50 cooled reagent positions weight'

Items tagged with '50 cooled reagent positions weight'

product image
Clinical Chemistry

Product Specification Automation Fully Automatic Brand Erba Model Name/Number EM200 Throughput 200 Photometric Tests/Hour & 400 Tests/Hour With ISE (Optional) Number Of Reagent Positions 50 Cooled Reagent Positions Weight Approx 120 Kg Dimension 810 x 800 x 600 mm (W x D x H) Sample Type Whole Blood, Serum, Plasma, Urin And, CSF Reading Volume 180 Micloliter Power Consumption 600 VA Reaction Tray 45 Hard Glass Cuvettes Minimum Order Quantity 1 Product Description Accurate Result Environment Friendly Cost Saving Consistent performance Quality & Service

Send Message
product image
Clinical Chemistry

The SAL 9000 Modular System delivers high throughput of chemistry and immunoassay testing by integrating Mindray BS-2000 Chemistry Analyzer and CL-6000i Chemiluminescence Immunoassay Analyzer, and new Sample Processing line SPL 2000. With patented automatic serum analysis design, SAL 9000 not only helps you optimize the management of lab space and manpower, it also offers highly reliable test results. Product Specification Automation Fully Automatic Brand Mindray Model Name/Number SAL 9000 Assays Clinical Chemistry Power Supply 230 V Reaction Cuvette Reusable Cuvette Storage 300000 Samples Features Seamless Integration Usage/Application Lab Wavelength 5000nm Number Of Reagent Positions 4 Weight 130kg Frequency 50 Hertz Power 45 Watt Product Description The SAL 9000 Modular System delivers high throughput of chemistry and immunoassay testing by integrating Mindray BS-2000 Chemistry Analyzer and CL-6000i Chemiluminescence Immunoassay Analyzer, and new Sample Processing line SPL 2000. With patented automatic serum analysis design, SAL 9000 not only helps you optimize the management of lab space and manpower, it also offers highly reliable test results. Features Maximize laboratory efficiency Integration: Optimize your lab’s customized arrangement with better automation system Efficiency: High-throughput chemistry and immunology modules for longer walk-away time Reliability: Ingenious and comprehensive analytic system provides reliable and accurate results Easy operation: Fully automated design,user-friendly operation interface and intelligent software function

Send Message
product image
Immunology Analyzer

Fully Automated Chemiluminescence Immunoassay Analyzer Introducing iFlash 1200, a chemiluminescence immunoassay analyzer that offers fully automated immunoassay analysis using Magnetic particle-based Direct Chemiluminescence technology. With a high throughput of up to 120 tests per hour and a first result available in just 13 minutes, iFlash 1200 is one of the fastest and most efficient immunoassay analyzers available on the market. The instrument features continuous STAT sample loading capacity with 16 sample positions, continuous reagents loading capacity with 15 reagent positions, and continuous loading of reaction vessels with a capacity of 500 cuvettes. Additionally, iFlash 1200 uses Acridinium Ester Labeled Direct Chemiluminescence for highly accurate and reliable results, and comes with ready-to-use reagents in convenient 2 x 50 tests pack size for simplified testing. Overall, iFlash 1200 is an innovative and versatile immunoassay analyzer that is perfect for laboratories that require high throughput and rapid turnaround times. iFlash 1200 chemiluminescence immunoassay analyzer Key Features: 1.Continuous loading of reagents with convenient pack size of 2 x 50 tests 2.Continous loading of 500 reaction cuvettes for longer walkaway time 3. 4 step magnetic separation for achieving high precision and quality results 4.Non contact vortex mixer-Highly Efficient technology to prevent carryover & cross contamination Additional information General Information Throughput : upto 120 tests/hour Time to First Results :13 minutes Detection Principle Magnetic particle Based Direct Chemiluminescence Chemiluminescence Label :Acridinium Ester Sample System Sample Position :16 sample position Types of Sample tube :Microcup & blood collecting tubes Sample Volume :5~150μL Reagent System Reagent Position :15 reagent positions with onboard refrigeration Reagent Carousel Temp :2-8 °C Reagent Detection :Reagent Level Tracking Reagent Pack : 2 x 50 tests Reagent Carousel Incubation Capacity :48 reaction vessels Incubation Temperature :37°C+-0.3°C Mixing System :Non-Contact Vortex Mixer Operating Conditions Power Supply :100~240V, 50/60HZ Power Consumption :600VA Temperature :10~30°C Weight :120 Kg Reagents iFlash 1200 reagents iFlash 1200 reagents Pack size 2 x 50 Tests 28 days On board reagent stability 28 days Calibration stability Built in Calibrators for all Parameters

Send Message
product image
Clinical Chemistry

Best Semi Automatic Biochemistry Analyzer AT Smart from Accurex. AT SMART is a Biochemistry/Clinical Analyzer with a user-friendly and the human interface is via touch screen. It measures the optical densities of samples & calculates the sample concentration which are used for biochemical investigation. This Biochemistry Machine operates from near UV to visible range. Semi Auto Analyzer AT SMART is CE certified and has undergone rigors testing before being delivered to customers. About •SMART MAINTENANCE •SMART LIS •SMART INVENTORY MANAGEMENT REDUCED ERRORS: IT allows for the accurate collection of data, automated workflows & minimized waste. SAVES TIME: Patient monitoring can be done in real-time, saves engineers visiting time. BETTER PATIENT EXPERIENCE: A connected laboratory system creates an environment that meets each patient’s needs. INSTRUMENT BREAKDOWN MANAGEMENT: Real-time data helps to monitor instrument performance. ONLINE REACTION CURVES: • Real time reaction curve with special • Flagging gives confidence in patient reports. INTELLECTUAL SOFTWARE: • User friendly Device. • 150 Direct access test keys gives freedom to select parameters easily. • Availability of different assay modes. DRY BATH INCUBATOR: • Dry bath incubator with 12 test tube positions • Mini size with 15 minutes start up time FEATURES: •Remote access & monitoring via Internet •150 test parameters •Built-in thermal printer to print results, enzymatic curves and standard calibration curves •Large graphic display with real time graph display for enzymatic reaction •Touch screen interface with dynamic test access key SPECIFICATIONS: Methodology- • Absorbance • Endpoint with standard, factor, sample blank & diffrential • Two-point (fixed time) and multi point kinetics • Multi standard calibration • Mono or bi-chromatic reading • Turbidimetry Optical System- • Principle: photometry • Range of measurement: 0.0-3.0A • Spectral range selection: Automatic via filter wheel • Filters: 340, 405, 505, 546, 578 and 630 nm plus two free position • Bandwidth:10nm (+/- 2nm) • Light source: Life Long Halogen lamp • Blanking: Automatic • Detector: Silicon Photodiode Photometer- • Peltier regulated 25ºC, 30ºC and 37ºC • Flow cell of 18 µ L • Continuous flow system with peristaltic pump • Programmable Sipping Volume Memory- • 150+ User Defined Test Programs • 1000 test results in instrument memory and unlimited test resultresult storage via cloud • Reagent Blank • 2 Level of QC Quality Control- • Levy-Jennings chart using westgard’s rules • 30 Normal and abnormal QC values for selected test User Interface- • Graphic LCD back Lit 240×64 pixels • Touch Screen input • Data port and cloud connectivity • Type : Graphic thermal printer Power & Dimensions- • Voltage : 220 V • Frequency : 50 Hz • Maximum power : < 150 VA • Maximum relative humidity : 75% • Compact form factor • Weight: < 6kgs Safety Information Precautions • Instrument should be operated only by authorised or trained personnel • For any reasons, unauthorised personnel should not be engaged for servicing or removing the cabinet • Power source should be regulated either by voltage stabilizer or regulated power back up (UPS). If inverter is been used, please ensure there exists a voltage stabilizer • Reagents recommended by the company to be preferably used • Flow cell needs to be rinsed regularly with the company recommended flow cell cleaning solution • User is requested not to use any other pointing devices other than being supplied by company while operating touch screen • The operating environment should be clean and protected from direct sunlight • During the day at the end of the work, it should be ensured that flow cell is always filled with distilled water • During transport / longer duration of shut down, th Direction for Use Please ensure that the power source is properly grounded and voltage between Line and Ground is less than 2V AC – 5V AC. • Please ensure that the instrument is placed on a firm table, clean environment, and sufficient ventilation space. • Switch On the instrument. • Instrument will run its own internal diagnostic routines, to ensure proper working of critical functions. • Allow the instrument to stabilize for 10 minutes. • During the stabilization time, please wash the flow cell with cleaning solution and distilled water for at least two times. • During shut down, ensure that the flow cell is cleaned with flow cell cleaning solution and rinsed thoroughly using distilled water. • For overnight shutdown, please ensure flow cell is filled with distilled water. • Cover the instrument with the given dust cover Other Info GENERAL INFORMATION While installing and setting up the instrument, few safety warnings and general precautions described in the further sections must be observed. A. Power Supply : • Power source should be grounded and have either servo stabilizer or regulated power back up • Power cord should be CE , CSA and UL marked • Voltage : 115 – 230 Volts ± 10% 50 – 60 Hz • Grounding: Make sure that electrical power source is properly grounded.

Send Message
product image
Clinical Chemistry

The HumaStar 80 is a clinical chemistry analyzer that combines the low maintenance effort of photometers with the convenience of automated sample processing. Its key features include autodiagnosis for electronic and mechanical components, emergency sample analysis and LIS interface. Highlights Original instrumentation provided by Human Diagnostics Diamond Down-To-Frame® refurbishment provided. Refurbishment includes disassembly and total restoration. Process continues with assembly, repair, and diagnostics. Certification concludes with calibration, QC and QA validation. Contact Diamond for pricing, specifications and availability. Assays Total assays tested: 48 - Acid Phosphatase (ACP), Alanine Aminotransferase (ALT) Entry-level, optimized batch analyzer > Up to 80 tests per hour > 40 tests per hour typical> 20 reagents on board> 54 sample positions> 18 μl micro flow cell> STAT function> Intelligent optimized batch mode> English, French, Italian, Spanish software> Automatic re-run with sample dilution> Integrated maintenance schedule> Built-in QC management> Heated pipetting system> Dimensions: 72 x 73 x 45 cm > Net weight: 42 kg> 230/110 Vac, 350

Send Message
product image
Clinical Chemistry

Product Specification Model Name/Number HumaStar 200 Brand Human Automation Fully Automatic Display Digital Dimensions 69 x 76 x 52 cm (WxDxH) Frequency 50/60 Hz Voltage 220-240 or 110-120 Vac Temperature 16-30 Degree C Throughput Up to 200 t/h throughput Weight 51 kg Reaction volume 210-350 il Wash station 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Languages English, French, Spanish Software (other languages can be added) Humidity < 80 % non-condensing Data External computer required (Pentium IV, 2 GHz Mode Open, random-access, STAT Product Description Product Detail : Unique Random-Access Analyzers for Small to Medium Size Laboratories Unique design Unique software architecture Unique features Analysis Endpoint (bichromatic), Differential endpoint (with sample blank), Fixed time, Kinetic (bichromatic) Multi-standard (up to 8), factor, linear, non linear (cubic-spline, poly-linear and logit-log four parameters) Samples Removable sample tray 60 positions: primary tubes 12–12.5x100 mm and 10 mm cups Optional: sample tray for 20 primary tubes 12–16x100 mm and 20 cups 3.5 ml Sample volume: 2–300 µl Internal barcode reader Automatic pre- and post-dilution Test profiles and replicates Reagents Removable reagent tray 30 reagent / diluent positions 50 and 20 ml bottles, adapter for tubes and cups Reagent volumes: 5–350 µl Refrigeration to ~9 Degree C below ambient (at bottom of bottle) Substrates, Enzymatic, Turbidimetric Reaction Reaction volume: 210–350 µl 80 reusable Bionex® cuvettes 6 mm optical path Heat transfer by air Pipetting Needle shock detector Capacitive liquid level detector Wash station 8-step cuvette wash station Systemic and special washing solution HumaStar 200: 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Optical system 9 discrete wavelengths (340, 405, 505, 546, 578, 600, 650, 700 nm, one free position) Band pass: +/– 5 nm Photometric linearity: 0–2.5 Abs Stability: <1 % drift per day Management 20 GB HDD, 512 MB RAM, CD/R, USB) Windows 7® with .NET framework 4.0 English, French, Spanish OS recommended Core i3TM or dedicated graphic card recommended Minimum 900 dots resolution Designed for touch screen (1280x1024 pixel) LIS: Bi-directional, polling mode, ASTM, ethernet Printouts By patient, single test, complete sample, work sheet, method and QCs, calibration curves, kinetics, continuous printing

Send Message
product image
Clinical Chemistry

As the workload and test menu increase, simultaneous management of multiple ELISA protocols can become challenging. The LisaXL has been designed with an open architecture to meet various laboratory needs, providing all the tools necessary for hands-free ELISA processing, increasing the reliability and reproducibility, improving throughput, and freeing the laboratory staff from repetitive steps. LisaXL allows running multiple parameters for over 250 samples in a single batch. Equipped with dual probes and dedicated workstations, drastically improve ELISA workflows. LisaXL is a complete walkway system that minimizes manual errors while improving the accuracy and turnaround time for critical tests. LisaXL provides the flexibility to build and run virtually any ELISA assays. Product Features: Lisa XL is a true walk-away system for any laboratory needs. High Throughput with 6 plates, can process up to 576 tests. A dynamic scheduler ensures optimized system usage and turnaround times by processing 6 plates and up to 12 assays in each plate Onboard flexibility with sample capacity up to 272 and 20 interchangeable racks for reagents and samples. Dual probe processing ensures speed and reliability. "Zero" carryover with high-quality disposable tips. Six individually controlled incubators and shakers with variable temperature, time, and speed settings. Efficient washing with super sweep mode ensures minimum residual volume, with up to 6 different wash buffers. Easy to use touchscreen graphic user interface Product Applications: ELISA Physical Specifications 1 Dimensions Length 1375 mm 55" Height 845 mm 33" Width 850 mm 33.5" Weight 195 kgs (Approx) Power Supply Voltage 100 - 240 Volts Frequency 50 / 60Hz Power consumption 700 W General Specifications Assay per plate Up to 12 Number of ELISA plates Up to 6 Sample capacity Up to 272 Sample / Reagent capacity Total 20 racks Single rack holds 16 sample / reagent tubes Double rack holds 6 x 60 ml reagent bottles (can be used interchangeably) Tip / Dilution box Total 11 locations of 96 capacity each (can be used interchangeably) Reader Specifications Reading Range 0.0 - 3.5 O.D Reading Channels 8 Filter wheel 8 positions 405 nm, 450 nm, 492 nm, 620 nm std* 578 nm and 700 nm optional + 2 open Light source Halogen Lamp Reading mode Single, Dual, ORR Reading time < 1 min (for single filter) Linearity Up to 3.0 O.D (450 nm) Washer Specifications Manifold configuration 16 needles - 8 aspiration & 8 dispensing Precision < 5 % at 300 μl Wash cycle Programmable Residual volume < 5 μl / well Soak time Programmable Washer buffer capacity 6 × 2.25 L Waste water container 1 × 20 L Incubator Specifications Number of incubators Up to 6 Temperature range RT + 5°C up to 50°C Temperature stability ± 1°C Incubation time Programmable Time to set temperature < 6 min Shaking 200 to 800 RPM Shaking Method Orbital Pipetting Specifications Number of probes 2 Tips 300 µl / 1000 µl, Auto / Manual selected Multi-dispensing (Reagent) Minimum volume 4 μl Serum dispensing time < 14 min Reagent dispensing time < 5 min Sample mixing Yes (Automatic) Precision Sample & Reagent Sample Dispensing with 300 µl tip: 3% above 10 µl ± 0.5 µl for 10 µl & less Reagent Dispensing with 300 µl tip: 3% for 25 µl & above Reagent Dispensing with 1ml tip: 5% for 75 µl & above" Process Security Liquid level sensing Well fill verification Clot detection Onboard sample identification Onboard reagent identification Strip verification Buffer sensing Alarms Software Operating System Windows 10 (Embedded) LIS interface Bi-directional, Serial / TCPIP USB Port Graphic load interface Graphical work list Data processing Quantitative, Semi-Quantitative & Qualitative Multi password access Ability to archive data Computer (Base configuration considered, higher configuration can be considered for upgrade after testing) Intel Core i3, 4 GB RAM, 1 TB hard disk Monitor 22" Full HD touch screen

Send Message
product image
Clinical Chemistry

EM 360 is a Fully Automated Clinical Chemistry Analyser which is time tested and proven technology. It is designed to provide the most demanding productivity, speed and operational ease. EM 360 with a throughput of 360 tests/hour offers flexibility in operation and rugged performance to win against high workload, tight deadlines, multiple tasks and complexity of testing. It yields high quality results for virtually any biochemistry test to deliver quick, efficient and consistent performance. Product Features: Automated, Discrete, Patient prioritized, Floor model Based on proven technology, Diffraction Grating Separate probes for Reagent R1 & R2 and dedicated probe for sample Low reading volume of 200 µl only Onboard cooling for reagents to enhance the reagent stability Barcode for reagents & samples (Optional) Wide test menu Product Applications: End Point Reactions: Glucose, Cholesterol, Triglycerides, Albumin, Total Protein, Uric Acid, Calcium, Magnesium, Bilirubin Total, Bilirubin Direct Kinetic Reactions: SGOT, SGPT, GGT, LDH, CK, CK MB, ALP, ACP, Amylase, Lipase Two Point Rate Reactions: Urea, Creatinine Immunoturbidimetric Chemistries: RA, CRP, ASO, Direct HDL, Direct LDL, Apo A, ApoB, Lp (a) Special Chemistries: HbA1c, Iron, Ferritin, Phosphorus, Microprotein, Ammonia, Bicarbonates System Type: Discrete, automated, random access, patient prioritized clinical chemistry analyzer Throughput: 360 tests / hour photometric and 600 tests / hour with ISE* (*optional ISE with Na+, K+, Cl-, Li+) Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry (optional) Barcode Reader: For reagents and samples (optional) Reaction Tray: 60 hard glass cuvettes Reaction Mixing: Stirrer with variable speed Minimum reaction Volume: 150 μl with maximum 200 μl reading volume On-board Laundry: 5 stage cleaning, 2 stage drying Photometer: Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700, 750 nm) OD Range: 0.0 - 3.0 Light Source: Halogen lamp Detector: Silicon photo-diode Water Consumption: < 10 litres Programmable Parameters: Default system pack parameters + upto 99 user defined parameters, Unlimited profile and unlimited calculation items Quality Control: QC plot data with QC rules. Provision for lab mean. Twin plot Calibration: K-Factor, Linear (1, 2 point & multipoint), 4P and 5P Logit-log, cubic spline, exponential, polynomial, On-board serial dilution for calibrator Power Requirement: AC 220 V ± 10 %, 50 Hz or AC 110 V ± 10 %, 60 Hz Power Consumption: 800 VA Dimension (mm): Approx. 675 (W) x 840 (D) x 1120 (H) Weight: Approx. 150 kgs. SAMPLE HANDLING Sample: Serum, Plasma, Urine, CSF, Whole blood, other Sample Unit: 82 positions for samples, blank , controls, calibrators, STAT sample Sample Pipetting: 2 - 70 µl (adjustable in 0.1 µl step) for Biochemistry, 70 µl fixed for ISE Capacitance probe with liquid level sensing & vertical obstruction detection, serum indices Auto Rerun: Repeat with same, increased or decreased volume ( upto 1:150) Sample Tubes /Cups: Primary tubes of 5 ml, 7 ml, 10 ml and sample cups REAGENT HANDLING Reagent Tray: 50 positions for reagents with onboard cooling Reagent Pipetting: R1: 50 - 300 µl (adjustable in 1 µl step) R2: 10 - 200 µl (adjustable in 1 µl step) Capacitance probe with level sensing & vertical obstruction detection SYSTEM INTERFACE: Analyzer-PC: USB PC - Host Computer: Bidirectional TCP / IP & RS - 232 PC - Printer: USB Operating System: Windows Based Database: Unlimited Results

Send Message
product image
Clinical Chemistry

Product Description: XL-640 with CRS is a random access, discrete, patient prioritized, fully automated clinical chemistry analyzer with autoloader designed to meet the needs of today’s modern clinical laboratories with high workload. Once samples are loaded, it is a complete walk-away system. XL 640 CRS is designed to operate smoothly over the long haul and to deliver consistent quality report. Product Features: Throughput of 400 tests/ hour (Photometric) and 640 tests/hour with ISE 56 Reagent Positions with On-board cooling for reagents 162 Sample positions with /Autoloader Separate probes for reagent R1 & R2 and dedicated probe for sample Clot detection for sample probe, Reflex testing and Serum Indices identification 72 permanent hard glass cuvettes with On-board Laundry Automatic dilution for high abnormal samples & Auto Rerun facility Extensive QC Programmes with Levy –Jennings Curve & QC rules. Automatic calculation for Mean SD & CV% Direct loading for primary tubes Touch screen User Friendly GUI with Bi-directional connectivity. System General System Type: Automated, Discrete, Random Access, Patient Prioritized Clinical Chemistry Analyzer with Autoloader Throughput: 400 photometric tests/hour & 640 tests/hour with ISE (*optional ISE with Na, K, Cl, Li) Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry(optional) Barcode Reader: Both for Samples & Reagents (Optional) Reactions Tray: 72 hard glass cuvettes Reaction Mixing: Dual Stirrer with variable speed Reading Volume: 180 µl On-Board Laundry: 6 stage cleaning, 2 stage drying Photometer: Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700 & 750 nm) O.D. Range: 0 - 3.0 Light Source: Halogen Lamp Detector: Silicon Photodiodes Water Consumption: < 14 liters/hour Programmable Parameters: Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items Quality Control: Q.C. plot data with Q.C. Rules. Provision for lab mean. Twin plot. Caliberation: K- factor, Linear (1,2 point and multipoint) 4P and 5P Logit-log, Cubic spline,exponential, polynomial. On-board serial dilution for calibrator Power Requirement: AC 220 V ± 10 %, 50 Hz or AC 110 V ± 10 %, 60 Hz Power Consumption: 800 VA Dimensions: Approximately 897 mm (w) x 655 mm (D) x 1170 mm (H) Weight: Approximately 200 Kg Sample Handling Sample: Serum, Plasma, Urine, CSF, Whole blood, other Sample Unit: upto 162 positions for samples/STAT/calibrator/controls with Autoloader Sample Pipetting: 2-70 µl (adjustable in 0.1 µl steps) for biochemistry,70 µl fixed for ISE capacitance probe with liquid level sensing and vertical obstruction detection , clot detection and serum indices and Reflex Testing Auto Rerun: Repeat with same, increade and decresaed volume (upto 1:150) Sample Tubes/Cups: Primary tubes of 5 ml, 7ml and 10 ml and sample cups Reagent Handling Reagent Tray: 56 positions for reagents with on-board cooling Reagent Pipetting: R1: 60 - 300 µl (Adjustable in 1 µl step) R2: 0 or 10 - 300 l (Adjustable in 1 µl step) Capacitance probe with level sensing and vertical obstruction detection System Interface Analyzer-PC: USB PC- HOST Computer: Bidirectional TCP/IP and RS - 232 PC- Printer: USB Operating System: Windows based with Touch Screen User Friendly GUI Database: Unlimited Results

Send Message

Still searching for
50 cooled reagent positions weight?