Jaipur
+918529833535

'4 wavelengths'

Items tagged with '4 wavelengths'

product image
Urinalysis Analyzer

Palm-sized, fitting easily into a doctor's bag or uniform pocket. The printer can be separated from the "PocketChem" analyzer, leaving it with a weight of just 180g. Corrective features for obtaining accurate test results Accurate readings can be obtained by eliminating the effects of chromaturia using the color correction test pad, by compensating measurements for the temperature of the surrounding environment using a built-in temperature sensor and by correcting specific gravity based on pH readings. Palm-sized analyzer driven by two batteries The analyzer is detachable from the printer. The analyzer is really portable and mobile. Simple operation. Just press the start button Measurement is performed by simply pressing the start button and placing a test strip. Test results can be simultaneously viewed on the display and printed out from the printer. Reliable test results with Creatinine correction Even with the use of spot urine, test results are reliable and are not affected by urine dilutions or concentrations. The P/C ration or A/C ratio is effective for the screening of renal diseases. Sample Urine Test strips AUTION Sticks/ Uriflet S (9UB)* / AUTION SCREEN * Except devices with 10V specifications Measurement items GLU (glucose), PRO (protein), BIL (bilirubin), URO (urobilinogen), S.G. (specific gravity), BLD (blood), PH (pH), KET (ketones), NIT (nitrite), LEU (leukocytes), CRE (creatinine) and ALB (albumin). Measurement principle Test strip: Dual wavelength reflectance method. (one wavelength for BLD measurement) Measurement wavelengths 3 wavelengths LED (565, 635, 760 nm) Sample supply method Manual dipping Measurement capacity 50 tests per hour Test strip reaction time About 60 seconds per test Measurement types Normal measurement and check measurement Display Custom LCD that displays information including type of test strip, measurement number (up to 4 digits), patient ID (up to 13 digits) and test results. Operator panel Panel sheet that provides 14 buttons including numeric buttons and start button. Memory capacity Test results for 100 samples External output Compliant with RS-232 C Measurement environment Temperature: 10 to 30 °C; Humidity: 30 to 60 % R.H. (non-condensing) *Temperature correction function used Dimensions 124 (W) x 81 (D) x 36 (H) mm Weight 180 g (without batteries) Power supply Instrument only: Two AA alkaline batteries or AC adapter Instrument with printer: AC adapter 7.5 V 3 A Power consumption 3 W Printer specifications Printer Thermal recording printer Printer paper High color development thermal paper (W 58 mm x φ26 mm) Dimensions 125 (W) x 133 (D) x 36 (H) mm Weight 180 g (without printer paper) Power supply AC adapter 7.5 V 3 A Power consumption 20 W

Send Message
product image
Urinalysis Analyzer

High Performance "Full Automated System" Color Touch Panel for good usability 7 inch WVGA color touchscreen with high operability displays measurement results, instrument conditions and operating instructions. "Sample delivery system" enables micro volume samples to be measured As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume. Sample Urine Test items Glu, Pro, Bil, Uro, Ket, pH, Nit, Bld, Leu, S.G., Alb, Cre(Alb/Cre ratio, Pro/Cre ratio can be calculated), turbidity and color tone Wavelength 5 LED wavelengths (430, 500, 565, 635, 760nm) Measurement principle Test strip :Dual-wavelength reflectance method (One-wavelength for Bld) Specific gravity :Reflection refractometryColor hue :Light-transmission measurementTurbidity :Light-scattering measurement method Test strip AUTION Sticks (10EA & 10PA) , Uriflet S 11UA Reaction time Approximately 60 seconds Throughput 225 samples per hour Strip storage Maximum 400 strips (200 strips x 2 feeder boxes) Required sample volume Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL Sample consumption Normal, STAT measurement: Maximum 0.90 mL Small volume measurement: Maximum 0.45 mL Sample container Sample tubes (length: 95 - 110 mm, diameter: ø14.0 - 15.8 mm) Maximum sample load 100 samples (Circulation) Data memory Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests Display Large color liquid crystal display (800 × 480 dots) Built-in printer 58-mm width printer paper (24 digits) External output 1 port (Replaceable with the optional Ethernet terminal) Communication method RS-232C compliant (Switchable between one-way and two-way) Measurement environment Temperature: 10 - 30°C; Humidity: 30 - 60% RH (No condensation) Power requirements 100 - 240 V AC (Maximum power line fluctuation of ±10%), 50/60 Hz Power consumption 150VA (Maximum) Dimensions 530 (W) × 530 (D) × 550 (H) mm (including the sampler) Weight Main body: Approximately 36 kg Sampler: Approximately 4 kg

Send Message
product image
Clinical Chemistry

Product Description: XL-640 with CRS is a random access, discrete, patient prioritized, fully automated clinical chemistry analyzer with autoloader designed to meet the needs of today’s modern clinical laboratories with high workload. Once samples are loaded, it is a complete walk-away system. XL 640 CRS is designed to operate smoothly over the long haul and to deliver consistent quality report. Product Features: Throughput of 400 tests/ hour (Photometric) and 640 tests/hour with ISE 56 Reagent Positions with On-board cooling for reagents 162 Sample positions with /Autoloader Separate probes for reagent R1 & R2 and dedicated probe for sample Clot detection for sample probe, Reflex testing and Serum Indices identification 72 permanent hard glass cuvettes with On-board Laundry Automatic dilution for high abnormal samples & Auto Rerun facility Extensive QC Programmes with Levy –Jennings Curve & QC rules. Automatic calculation for Mean SD & CV% Direct loading for primary tubes Touch screen User Friendly GUI with Bi-directional connectivity. System General System Type: Automated, Discrete, Random Access, Patient Prioritized Clinical Chemistry Analyzer with Autoloader Throughput: 400 photometric tests/hour & 640 tests/hour with ISE (*optional ISE with Na, K, Cl, Li) Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry(optional) Barcode Reader: Both for Samples & Reagents (Optional) Reactions Tray: 72 hard glass cuvettes Reaction Mixing: Dual Stirrer with variable speed Reading Volume: 180 µl On-Board Laundry: 6 stage cleaning, 2 stage drying Photometer: Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700 & 750 nm) O.D. Range: 0 - 3.0 Light Source: Halogen Lamp Detector: Silicon Photodiodes Water Consumption: < 14 liters/hour Programmable Parameters: Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items Quality Control: Q.C. plot data with Q.C. Rules. Provision for lab mean. Twin plot. Caliberation: K- factor, Linear (1,2 point and multipoint) 4P and 5P Logit-log, Cubic spline,exponential, polynomial. On-board serial dilution for calibrator Power Requirement: AC 220 V ± 10 %, 50 Hz or AC 110 V ± 10 %, 60 Hz Power Consumption: 800 VA Dimensions: Approximately 897 mm (w) x 655 mm (D) x 1170 mm (H) Weight: Approximately 200 Kg Sample Handling Sample: Serum, Plasma, Urine, CSF, Whole blood, other Sample Unit: upto 162 positions for samples/STAT/calibrator/controls with Autoloader Sample Pipetting: 2-70 µl (adjustable in 0.1 µl steps) for biochemistry,70 µl fixed for ISE capacitance probe with liquid level sensing and vertical obstruction detection , clot detection and serum indices and Reflex Testing Auto Rerun: Repeat with same, increade and decresaed volume (upto 1:150) Sample Tubes/Cups: Primary tubes of 5 ml, 7ml and 10 ml and sample cups Reagent Handling Reagent Tray: 56 positions for reagents with on-board cooling Reagent Pipetting: R1: 60 - 300 µl (Adjustable in 1 µl step) R2: 0 or 10 - 300 l (Adjustable in 1 µl step) Capacitance probe with level sensing and vertical obstruction detection System Interface Analyzer-PC: USB PC- HOST Computer: Bidirectional TCP/IP and RS - 232 PC- Printer: USB Operating System: Windows based with Touch Screen User Friendly GUI Database: Unlimited Results

Send Message
product image
Biochemistry Analyzer

Yumizen CA40 Semi-automated Clinical Chemistry Analyzer: Yumizen CA40 is a semi-automated Clinical Chemistry analyzer with facility to perform Chemistry, Immunoturbidimetry and Coagulation Tests (PT & APTT). It is an ideal solution for small laboratories with the facility to perform a wide range of biochemical tests. Specification:- Semi-automated Clinical Chemistry analyzer with coagulation tests capacity (PT & APTT) 8 incubation positions for chemistry tests and 5 positions for coagulation tests 8-inch colored touch screen display Tri-level Quality Control with Levey-Jennings chart 6 filters with additional 2 open positions Show less

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ T4 Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Thyroxine (Total T4) in human whole blood, serum or plasma. The test is used as an aid to the assessment of thyroid function. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ fT4 Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative determination of free thyroxine (fT4) in human whole blood, serum or plasma. The test is used as an aid to the assessment of thyroid function. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
Rapid Test

Intended Use HIV Ag & Ab Card (4th Generation) is a visual, rapid qualitative and sensitive solid phase immunochromatographic assay for the differential detection of HIV-1 p24 Antigen and Antibodies (IgM, IgG & IgA) to HIV-1& HIV-2 in Human Serum/ Plasma/ Whole blood (collected by venipuncture or Fingerprick). The test is a screening test for p24 antigen (HIV-1) and HIV antibodies (anti-HIV-1 & anti-HIV-2) and is for in vitro diagnostic use only. It is intended for screening of blood donors or other individuals at risk for HIV-1 & HIV-2 infection and for clinical diagnostic testing. It is a screening test for p24 antigen (HIV-1) and HIV antibodies (anti-HIV-1 & anti-HIV-2). The test is for in vitro diagnostic use only and is intended for screening of blood donors or others individuals at risk for HIV-1 and/or HIV-2 infection and for clinical diagnostic testing. Salient Features • Finger prick, rapid, visual and qualitative Immunoassay. • 4TH Generation Rapid test for differential detection of p24 Antigen & antibodies for HIV in serum/plasma /whole blood. • Ideal for Blood screening, detects sero-negative HIV Cases. • Use of gp-41, C terminus of gp120 for HIV-1 , gp-36 for HIV -2 antibodies and Anti-p24 for HIV p24 Ag detection. • Detection of Group ‘0’ & subtype ‘C’ of HIV-1, which is most prevalent in India. • Based on Immunochromatography Technique. • See through device for easy interpretation of results. • Sensitivity : 100 % & Specificity: 100% • Analytical Sensitivity of HIV p24 Ag : 100 IU/ml (traceable to p24 Antigen NIBSC Standard, U.K. Code No. 90/636) • Long Shelf life 30 months at 2-30°C • Convenient pack size: 25 T.

Send Message

Still searching for
4 wavelengths?