product image
Clinical Chemistry

ADVIA 2400 Chemistry System The right balance of speed and efficiency The ADVIA® 2400 Clinical Chemistry System manages the most demanding workloads and meets high turnaround-time (TAT) goals. Its menu includes methods for testing drugs-of-abuse, therapeutic drugs (TDM) and new assays such as cystatin C and CardioPhase® hsCRP. The ADVIA 2400 Clinical Chemistry System offers: High throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage heavy workloads Rapid, consistent, 2-second cycle time for faster tube speed and test throughput User-defined automatic repeat, dilution, and reflex testing Large onboard reagent capacity and optional concentrated reagents help to minimize intervention demands Refrigerated onboard storage of controls and reagents for extended stability and increased productivity Automation-ready design: no additional hardware required Features & Benefits The ADVIA 2400 Clinical Chemistry System meets today’s high turnaround-time goals with a throughput of up to 2400 tests/hour. In addition to assays for general and specialty chemistries, its menu includes assays for specific protein measurement, drugs-of-abuse testing (DAT), and therapeutic drug monitoring (TDM). Interesting new assays such as cystatin C, HbA1c with automated sample pretreatment, and CardioPhase® hsCRP can now be included in your routine testing. The ADVIA 2400 Chemistry System pushes productivity levels while maintaining the reliability and stability that keep laboratories up and running. A rapid, 2-second probe cycle time maximizes tube speed and test throughput and combines with the system’s efficient automation-readiness to provide the turnaround time needed for high-volume laboratories Superior Speed and Productivity Throughput of up to 2400 tests/hour (1800 photometric and 600 ISE) to manage the heaviest workloads Rapid, consistent, 2-second cycle time Throughput of 200 tubes per hour, even when running three ISE tests and nine photometric tests per sample Automatic Sample Retain technology, auto-repeat, auto-dilution, and auto-reflex testing Automation-ready Point-in-space aspiration enables connectivity to a track. Redundant sample loading provides built-in backup and easy handling of non-routine samples. Direct sampling from track prevents tubes being detained at an analyzer and reduces aliquoting. Minimal Need for Operator Intervention Minimal-maintenance ISEs Large onboard reagent capacity and optional concentrated reagents for fewer interruptions No-maintenance, 37°C incubation oil bath Auto-calibration and auto-QC from refrigerated onboard calibrators and controls Microvolume technology with 32,000 tests onboard and up to 60 days' onboard stability for improved walkaway time. Concentrated reagents for increased maximum capacity. Remote diagnostics and Inter-Laboratory Quality Control (ILQC) options Exceptional Reliability Sample integrity check for icterus, hemolysis, and lipemia Sample probe with automatic clot/clog detection, liquid-level sensing, short-sample detection, and crash protection Advances in onboard reagent stability, calibration frequency, reduction in interferences, and expanded assay linearity

Send Message
product image
Hemostasis Analyzer

Product Description: It’s an advanced analyzer for Complete Hemostasis. This four channel coagulation analyzer redefines the benefits in its class. Erba ECL 412, can perform PT, APTT, Fibrinogen, Thrombin Time , All Factors, Lupus , Protein S, Protein C , Antithrombin III and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant, Protein S performed using Light scatter principle. Protein C, Antithrombin III done by Chromogenic Principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting test Cuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 412 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centers It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc General Specifications: 4 channel semi-automated hemostasis instrument It can perform 4 simultaneous tests of the same parameter Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second row of assay preparation/incubation during the analysis of the current line, using preparation line option It can run assays in single or duplicate (programmable per assay) Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Chromogenic (colorimetry at 405nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 300 x 290 x 90 mm Weight : 3 kgs Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply: 100-240 VAC and 50/60 Hz Power Consumption: 45 Watts In-Rush Power: 150VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control names total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 600 results for QC determinations (run in duplicate) Up to 900 results for patients (run in duplicate) New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pendrive. Regular backup and file purging is recommended from the USB pendrive to insure rapid operations. (We recommend at least a monthly purge from a computer to back up and remove CH files) USB pendrive , FAT32 formatted

Send Message
product image
Biochemistry Analyzer

Yumizen CA40 Semi-automated Clinical Chemistry Analyzer: Yumizen CA40 is a semi-automated Clinical Chemistry analyzer with facility to perform Chemistry, Immunoturbidimetry and Coagulation Tests (PT & APTT). It is an ideal solution for small laboratories with the facility to perform a wide range of biochemical tests. Specification:- Semi-automated Clinical Chemistry analyzer with coagulation tests capacity (PT & APTT) 8 incubation positions for chemistry tests and 5 positions for coagulation tests 8-inch colored touch screen display Tri-level Quality Control with Levey-Jennings chart 6 filters with additional 2 open positions Show less

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ T4 Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Thyroxine (Total T4) in human whole blood, serum or plasma. The test is used as an aid to the assessment of thyroid function. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ fT4 Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative determination of free thyroxine (fT4) in human whole blood, serum or plasma. The test is used as an aid to the assessment of thyroid function. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Testosterone Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative measurement of Testosterone in human whole blood, serum or plasma. The test is to be used as an aid in the diagnosis of diseases related to abnormal testosterone levels. STORAGE AND STABILITY 1. Store the test kit at 4~30ºC up to the expiration date printed on the package. 2. If removed from refrigerator, allow the test to return to room temperature for 30 minutes before testing. 3. Do not remove the cassette from the pouch until ready to use. The test cassette should be used within 1 hour once opened.

Send Message
product image

Intended Use The 4th Generation HCV TRI-DOT is a rapid, visual, sensitive and qualitative in vitro diagnostic test for the detection of (IgM,IgG & IgA) antibodies to Hepatitis C virus in human serum or plasma. It has been developed and designed with increased sensitivity for core and NS3 antibodies using a unique combination of modified HCV antigen. Salient Features Based on “Flow Through Technology”, which is similar to Elisa technology because of involvement of washing steps at various levels to enhance the specificity. Use of highly purified HCV antigens for Core, NS3, NS4, NS5 immobilized on the device. Detection of all the subtypes of HCV. Results within 3 minutes. In built quality control dot which validates the test. 100% Sensitivity & 98.9% Specificity as per WHO evaluation. Shelf life : 24 months at 2-8°C

Send Message
product image
Rapid Test

Intended Use HIV Ag & Ab Card (4th Generation) is a visual, rapid qualitative and sensitive solid phase immunochromatographic assay for the differential detection of HIV-1 p24 Antigen and Antibodies (IgM, IgG & IgA) to HIV-1& HIV-2 in Human Serum/ Plasma/ Whole blood (collected by venipuncture or Fingerprick). The test is a screening test for p24 antigen (HIV-1) and HIV antibodies (anti-HIV-1 & anti-HIV-2) and is for in vitro diagnostic use only. It is intended for screening of blood donors or other individuals at risk for HIV-1 & HIV-2 infection and for clinical diagnostic testing. It is a screening test for p24 antigen (HIV-1) and HIV antibodies (anti-HIV-1 & anti-HIV-2). The test is for in vitro diagnostic use only and is intended for screening of blood donors or others individuals at risk for HIV-1 and/or HIV-2 infection and for clinical diagnostic testing. Salient Features • Finger prick, rapid, visual and qualitative Immunoassay. • 4TH Generation Rapid test for differential detection of p24 Antigen & antibodies for HIV in serum/plasma /whole blood. • Ideal for Blood screening, detects sero-negative HIV Cases. • Use of gp-41, C terminus of gp120 for HIV-1 , gp-36 for HIV -2 antibodies and Anti-p24 for HIV p24 Ag detection. • Detection of Group ‘0’ & subtype ‘C’ of HIV-1, which is most prevalent in India. • Based on Immunochromatography Technique. • See through device for easy interpretation of results. • Sensitivity : 100 % & Specificity: 100% • Analytical Sensitivity of HIV p24 Ag : 100 IU/ml (traceable to p24 Antigen NIBSC Standard, U.K. Code No. 90/636) • Long Shelf life 30 months at 2-30°C • Convenient pack size: 25 T.

Send Message