Clinical Chemistry
Product Description:
XL-640 with CRS is a random access, discrete, patient prioritized, fully automated clinical chemistry analyzer with autoloader designed to meet the needs of today’s modern clinical laboratories with high workload. Once samples are loaded, it is a complete walk-away system. XL 640 CRS is designed to operate smoothly over the long haul and to deliver consistent quality report.
Product Features:
Throughput of 400 tests/ hour (Photometric) and 640 tests/hour with ISE
56 Reagent Positions with On-board cooling for reagents
162 Sample positions with /Autoloader
Separate probes for reagent R1 & R2 and dedicated probe for sample
Clot detection for sample probe, Reflex testing and Serum Indices identification
72 permanent hard glass cuvettes with On-board Laundry
Automatic dilution for high abnormal samples & Auto Rerun facility
Extensive QC Programmes with Levy –Jennings Curve & QC rules. Automatic calculation for Mean SD & CV%
Direct loading for primary tubes
Touch screen User Friendly GUI with Bi-directional connectivity.
System General
System Type: Automated, Discrete, Random Access, Patient Prioritized Clinical Chemistry Analyzer with Autoloader
Throughput: 400 photometric tests/hour & 640 tests/hour with ISE (*optional ISE with Na, K, Cl, Li)
Analytical Methods: 1-Point, 2-Point, Rate-A, Rate-B, Direct Potentiometry(optional)
Barcode Reader: Both for Samples & Reagents (Optional)
Reactions Tray: 72 hard glass cuvettes
Reaction Mixing: Dual Stirrer with variable speed
Reading Volume: 180 µl
On-Board Laundry: 6 stage cleaning, 2 stage drying
Photometer: Multi-wavelength diffraction grating with 12 wavelengths (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700 & 750 nm)
O.D. Range: 0 - 3.0
Light Source: Halogen Lamp
Detector: Silicon Photodiodes
Water Consumption: < 14 liters/hour
Programmable Parameters: Default system pack parameters + upto 99 user defined parameters, Unlimited profiles and unlimited calculation items
Quality Control: Q.C. plot data with Q.C. Rules. Provision for lab mean. Twin plot.
Caliberation: K- factor, Linear (1,2 point and multipoint) 4P and 5P Logit-log, Cubic spline,exponential, polynomial. On-board serial dilution for calibrator
Power Requirement:
AC 220 V ± 10 %, 50 Hz or
AC 110 V ± 10 %, 60 Hz
Power Consumption: 800 VA
Dimensions: Approximately 897 mm (w) x 655 mm (D) x 1170 mm (H)
Weight: Approximately 200 Kg
Sample Handling
Sample: Serum, Plasma, Urine, CSF, Whole blood, other
Sample Unit: upto 162 positions for samples/STAT/calibrator/controls with Autoloader
Sample Pipetting: 2-70 µl (adjustable in 0.1 µl steps) for biochemistry,70 µl fixed for ISE capacitance probe with liquid level sensing and vertical obstruction detection , clot detection and serum indices and Reflex Testing
Auto Rerun: Repeat with same, increade and decresaed volume (upto 1:150)
Sample Tubes/Cups: Primary tubes of 5 ml, 7ml and 10 ml and sample cups
Reagent Handling
Reagent Tray: 56 positions for reagents with on-board cooling
Reagent Pipetting:
R1: 60 - 300 µl (Adjustable in 1 µl step)
R2: 0 or 10 - 300 l (Adjustable in 1 µl step)
Capacitance probe with level sensing and vertical obstruction detection
System Interface
Analyzer-PC: USB
PC- HOST Computer: Bidirectional TCP/IP and RS - 232
PC- Printer: USB
Operating System: Windows based with Touch Screen User Friendly GUI
Database: Unlimited Results
Send Message