Hematology

Based on Mindray’s continuous innovation in hematology field, BC-5130 is especially tailored to assist diagnostic labs who need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget. As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5130 is a highly user-friendly and innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfill and exceed the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs. Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50 μm in diameter) provides better performance on samples with low PLT. Efficient Only three routine reagents are required. These have 2 years shelf life and also less consumed by BC-5130. Original QC and calibrator are also provided to ensure the hematology analyzer’s traceability and testing quality. WBC 5-Part differentiation,25 reportable parameters & 23 research parameters,3 histograms Whole blood Mode, Capillary whole blood mode & Prediluted Mode Tri-angle Laser Scatter + Chemical dye + Flow cytometry technology Dedicated optical counting channel for Basophil measurement 10.4 inch large TFT touch screen with user-friendly software Large storage capacity: Up to 1,50,000 samples Throughput:60 samples/Hour Compact Two kinds of lyse reagents are located inside of BC-5130, which helps the small labs to save space. BC-5130, the 5-part hematology analyzer offers a great solution for clinical labs, especially for those who have limited space. Its compact foot-print is a result of innovative technology improvements, including miniaturized semi-conductor laser source, highly integrated electronic boards and optimized liquid handling system. BC-5130 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs. Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5130 has higher dilution ratio than other 5-part hematology There’s NLR parameter in each CBC+DIFF result. Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. BC-5130 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well. Technology Compared with traditional helium neon laser or argon laser, semi -conductor laser has smaller size, lower cost and longer life cycle.

Send Message
product image
Medical Equipment

In compliance with out-of-hospital patient transport standards such as EN1789, EN13718-1, IEC60601-1-12 and U.S. military standards, N1 is a highly competent solution for various out-of-hospital transport settings both on land and in air. The N1's exceptional reliability and strong performance enhance your confidence to provide seamless patient care during transport no matter intra or out of hospital. One monitor, Multiple solutions Mirror Mode Two-way screen or remote control functionality and viewing on both the 19" external display and the N1 unit - simultaneously. benevision-n1-fig2-2-pc BeneVision N1 as a Transport Monitor Enhanced data analysis greatly improves parameters' accuracy and anti-interference ability. Its fully integrated sidestream CO2 module monitors the patient's breathing situation by connecting with sampling line directly, freeing caregivers from the shackles of expanding external modules for transport. One monitor, Multiple solutions Mirror Mode Two-way screen or remote control functionality and viewing on both the 19" external display and the N1 unit - simultaneously. benevision-n1-fig2-2-pc BeneVision N1 as a Transport Monitor Enhanced data analysis greatly improves parameters' accuracy and anti-interference ability. Its fully integrated sidestream CO2 module monitors the patient's breathing situation by connecting with sampling line directly, freeing caregivers from the shackles of expanding external modules for transport. benevision-n1-fig2-1-pc BeneVision N1 as a Multi-Parameter Module Slide directly into the module slot or SMR of the N-Series monitor providing an expansive set of parameter measurements. When combined with our additional advanced parameter modules, this solution fits even the highest level of critical care environments. benevision-n1-fig2-3-pc Companion Mode Connect with N-Series host monitor via cable connection to N1 dock and have the ability for dual-screen monitoring and bi-directional control of the bedside monitor - expanding slot space for more advanced parameters and enhanced ICU workflow. Patient-Centric Data Collection When connected to a bedside patient monitor, advanced parameters collected from the host monitor such as AG and BIS, etc., will also be stored in N1 with trend data and alarm events reviewable even when it is disconnected.

Send Message
product image
Laboratory Usage

Backed by a team of experienced professionals, we are offering Water & Soil Analysis Kits Digital with 7 Parameters. The given product is available on numerous specifications in promised time-frame as per the customer’s demand. Offered product is manufactured as per industry standard by our workforce at our manufacturing unit using finest material. This product is checked on numerous parameters so as to deliver a flawless range. Features: Precisely designed Easy to use Durability Product Details: Application Laboratory Use Brand Swastik Type Soil Analyzer Kit No of Parameter 7 Display Digital Usage To Analyze Water and Soil

Send Message
product image
Immunology Analyzer

Fully Automated Chemiluminescence Immunoassay Analyzer Introducing iFlash 1200, a chemiluminescence immunoassay analyzer that offers fully automated immunoassay analysis using Magnetic particle-based Direct Chemiluminescence technology. With a high throughput of up to 120 tests per hour and a first result available in just 13 minutes, iFlash 1200 is one of the fastest and most efficient immunoassay analyzers available on the market. The instrument features continuous STAT sample loading capacity with 16 sample positions, continuous reagents loading capacity with 15 reagent positions, and continuous loading of reaction vessels with a capacity of 500 cuvettes. Additionally, iFlash 1200 uses Acridinium Ester Labeled Direct Chemiluminescence for highly accurate and reliable results, and comes with ready-to-use reagents in convenient 2 x 50 tests pack size for simplified testing. Overall, iFlash 1200 is an innovative and versatile immunoassay analyzer that is perfect for laboratories that require high throughput and rapid turnaround times. iFlash 1200 chemiluminescence immunoassay analyzer Key Features: 1.Continuous loading of reagents with convenient pack size of 2 x 50 tests 2.Continous loading of 500 reaction cuvettes for longer walkaway time 3. 4 step magnetic separation for achieving high precision and quality results 4.Non contact vortex mixer-Highly Efficient technology to prevent carryover & cross contamination Additional information General Information Throughput : upto 120 tests/hour Time to First Results :13 minutes Detection Principle Magnetic particle Based Direct Chemiluminescence Chemiluminescence Label :Acridinium Ester Sample System Sample Position :16 sample position Types of Sample tube :Microcup & blood collecting tubes Sample Volume :5~150μL Reagent System Reagent Position :15 reagent positions with onboard refrigeration Reagent Carousel Temp :2-8 °C Reagent Detection :Reagent Level Tracking Reagent Pack : 2 x 50 tests Reagent Carousel Incubation Capacity :48 reaction vessels Incubation Temperature :37°C+-0.3°C Mixing System :Non-Contact Vortex Mixer Operating Conditions Power Supply :100~240V, 50/60HZ Power Consumption :600VA Temperature :10~30°C Weight :120 Kg Reagents iFlash 1200 reagents iFlash 1200 reagents Pack size 2 x 50 Tests 28 days On board reagent stability 28 days Calibration stability Built in Calibrators for all Parameters

Send Message
product image
Clinical Chemistry

Best Semi Automatic Biochemistry Analyzer AT Smart from Accurex. AT SMART is a Biochemistry/Clinical Analyzer with a user-friendly and the human interface is via touch screen. It measures the optical densities of samples & calculates the sample concentration which are used for biochemical investigation. This Biochemistry Machine operates from near UV to visible range. Semi Auto Analyzer AT SMART is CE certified and has undergone rigors testing before being delivered to customers. About •SMART MAINTENANCE •SMART LIS •SMART INVENTORY MANAGEMENT REDUCED ERRORS: IT allows for the accurate collection of data, automated workflows & minimized waste. SAVES TIME: Patient monitoring can be done in real-time, saves engineers visiting time. BETTER PATIENT EXPERIENCE: A connected laboratory system creates an environment that meets each patient’s needs. INSTRUMENT BREAKDOWN MANAGEMENT: Real-time data helps to monitor instrument performance. ONLINE REACTION CURVES: • Real time reaction curve with special • Flagging gives confidence in patient reports. INTELLECTUAL SOFTWARE: • User friendly Device. • 150 Direct access test keys gives freedom to select parameters easily. • Availability of different assay modes. DRY BATH INCUBATOR: • Dry bath incubator with 12 test tube positions • Mini size with 15 minutes start up time FEATURES: •Remote access & monitoring via Internet •150 test parameters •Built-in thermal printer to print results, enzymatic curves and standard calibration curves •Large graphic display with real time graph display for enzymatic reaction •Touch screen interface with dynamic test access key SPECIFICATIONS: Methodology- • Absorbance • Endpoint with standard, factor, sample blank & diffrential • Two-point (fixed time) and multi point kinetics • Multi standard calibration • Mono or bi-chromatic reading • Turbidimetry Optical System- • Principle: photometry • Range of measurement: 0.0-3.0A • Spectral range selection: Automatic via filter wheel • Filters: 340, 405, 505, 546, 578 and 630 nm plus two free position • Bandwidth:10nm (+/- 2nm) • Light source: Life Long Halogen lamp • Blanking: Automatic • Detector: Silicon Photodiode Photometer- • Peltier regulated 25ºC, 30ºC and 37ºC • Flow cell of 18 µ L • Continuous flow system with peristaltic pump • Programmable Sipping Volume Memory- • 150+ User Defined Test Programs • 1000 test results in instrument memory and unlimited test resultresult storage via cloud • Reagent Blank • 2 Level of QC Quality Control- • Levy-Jennings chart using westgard’s rules • 30 Normal and abnormal QC values for selected test User Interface- • Graphic LCD back Lit 240×64 pixels • Touch Screen input • Data port and cloud connectivity • Type : Graphic thermal printer Power & Dimensions- • Voltage : 220 V • Frequency : 50 Hz • Maximum power : < 150 VA • Maximum relative humidity : 75% • Compact form factor • Weight: < 6kgs Safety Information Precautions • Instrument should be operated only by authorised or trained personnel • For any reasons, unauthorised personnel should not be engaged for servicing or removing the cabinet • Power source should be regulated either by voltage stabilizer or regulated power back up (UPS). If inverter is been used, please ensure there exists a voltage stabilizer • Reagents recommended by the company to be preferably used • Flow cell needs to be rinsed regularly with the company recommended flow cell cleaning solution • User is requested not to use any other pointing devices other than being supplied by company while operating touch screen • The operating environment should be clean and protected from direct sunlight • During the day at the end of the work, it should be ensured that flow cell is always filled with distilled water • During transport / longer duration of shut down, th Direction for Use Please ensure that the power source is properly grounded and voltage between Line and Ground is less than 2V AC – 5V AC. • Please ensure that the instrument is placed on a firm table, clean environment, and sufficient ventilation space. • Switch On the instrument. • Instrument will run its own internal diagnostic routines, to ensure proper working of critical functions. • Allow the instrument to stabilize for 10 minutes. • During the stabilization time, please wash the flow cell with cleaning solution and distilled water for at least two times. • During shut down, ensure that the flow cell is cleaned with flow cell cleaning solution and rinsed thoroughly using distilled water. • For overnight shutdown, please ensure flow cell is filled with distilled water. • Cover the instrument with the given dust cover Other Info GENERAL INFORMATION While installing and setting up the instrument, few safety warnings and general precautions described in the further sections must be observed. A. Power Supply : • Power source should be grounded and have either servo stabilizer or regulated power back up • Power cord should be CE , CSA and UL marked • Voltage : 115 – 230 Volts ± 10% 50 – 60 Hz • Grounding: Make sure that electrical power source is properly grounded.

Send Message
product image
Clinical Chemistry

Find the Best Semi Automatic Biochemistry Analyzer from Accurex. Buy Acculab At 112 Plus (Semi Auto Biochemistry Analyzer) which is the best Biochemistry Machine with numerous features like Filter Check, Self-check operation for optical filters, Checks the absorbance of each of the 7 filters & free position, Ensures that all the filters are in good working condition. This Biochemistry Analyzer has Improved ergonomic touch screen display, ensures strain free viewing with End point, kinetic, fixed time & absorbance mode. FILTER CHECK • Self-check operation for optical filters. • Checks the absorbance of each of the 7 filters & free position. • Ensures that all the filters are in good working condition. WORKLIST • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. LAMP SAVING • Lamp saving option available ensuring long lamp life. • The lamp can be turned off in case of sporadic sample workload ALARMS • Audio alarm is sounded when results are higher (S) or lower (L) than reference range ensuring that all abnormal samples are flagged for further review. • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design Methodology: End point, kinetic, fixed time & absorbance Calibration: Single standard/multi-point linear/multi-point non-linear Programmable channels: 112 Memory: 3200 results Quality control: Comprehensive QC software with L-J graph Light source:Quartz-Halogen lamp 12V / 20W Photometric range: 0.0000 to 3.0000 Abs, Resolution : 0.0001 Abs : Drift : 0.002 Abs/hour Wavelength range: 7 standard filters: 340, 405, 492, 510, 546, 578, 630 nm & 1 free optional position ; Half Bandwidth < 8 nm : Stray light : < 1.0 % at 340 nm, Stainless steel body with quartz window; Optical path 10 mm Flowcell: Stainless steel body with quartz window; Optical path 10 mm Measuring volume: 32 μl Programmable aspiration volume:: 500-2000 μl Temperature control: Peltier elements : 25°C, 30°C & 37°C ±0.1°C Input: Ergonomic LCD touch screen display Printer: Built-in high speed thermal printer Interface: RS-232 serial port Dimension / Weight: 450 x 360 x 140 mm / 11.5 kgs Operating environment: Temperature: 15-30°C ; Humidity: 20-80 % Power requirement: AC 110-220 V ±10%, 50/60 Hz Safety Information • The position of the LCD display has been designed to reduce cervical (neck muscle) strain during continual use. • The aerial view display design makes it possible to view the screen from multiple perspectives, (standing or sitting, with equal clarity). Direction for Use • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. Other Info • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design

Send Message
product image
Hematology

Fully Automatic Oscar Om 511 Hematology Analyzer, For Clinical, User Input: Touch Instrument Name Haematology Analyzer Usage/Application All Automation Fully Automatic Brand OSCAR Parameters CBC + 5 Diff Differential Type 5-Part Number Of Chambers 2 User Input Touch / Manual Number Of Parameters ALL Parameters Instrument Type 5 PART Cell Counter Model Name/Number OM-511 Type Of Blood Analyzer Fully Automatic Sample Mode All Method All Throughput 60 Samples Per Hour Display Digital Features Catalogs Attached Sample Volume 15ul Storage 1 Lac Results No. Of Reagents Used 2 Lyse 1 Diluent Accessories Keyboard ,Mouse ,Tubing Set ,Power Adaptor, Print Roll Calibration Automatic / Manual Chamber Type Double Chamber Depth Of Chamber 100un Detector Yes Dilution Ratio 1.0 Loading Pattern Manual Measuring Method Electric Impedance & Cytometric Measuring Principle Electric Impedance & Cytometric Measuring Range 2 SD Measuring Time 52 Sec Number Of Reading Channels 2 Number Of Squares 4 Operating Voltage 220 Power Supply 220 Reagent System Close with RFID Sample Type Whole Blood Slide Size 0.3un Test Volume 15ul Wavelength 546 Weight 20 Kg Zero Setting Blank Aperture Size RBC 80 , WBC 100 , Plt 60 Is It Portable Yes Measurement Range Mm Hr 60 Test Per Hour Portable Yes Reading Chambers 2 Direct Sample Yes Optical System Wavelength Optical Source Flow cell Height 470mm Point Of Care Yes Dimension 365x470x525mm Printer Yes - Internal Humidity 88% Operational Ambient Temperature 37% Atmospheric Pressure 85 kpa User Interface Yes Reliable Yes Minimum Order Quantity 1 Product Description Company : OSCAR MEDICARE PVT LTD Brand : OM-511 CBC 5 Part Hematology Products Specification : The Brand New Autometed 5-Part Differentials hematology analyzer. Try-angular laser scatter + flow cytometry for 5 Part WBC Counting. Whole Blood, Peripheral Blood, Pre-diluted blood. Throughput with 60 Samples / hour. 29 Parameters (Include 4 research Parameters 3 Reagents with orignal QC & Carlibrators

Send Message
product image
Clinical Chemistry

Product Description: Fully Automated 5 Part Differential Analyser with continuous loading Product Features: Tri angle laser-based flow cytometry for WBC and differentials enumeration 33 reportable parameters including NLR, P-LCC, P-LCR, Mentzer index and RDWI 20 µl sample volume Throughput 80 samples/ hr Large storage capacity of 100000 samples Bidirectional Interfacing Large coloured LCD touch screen of 22 inch Product Application: CBC + Diff Analysis Mode Type: Whole Blood, Predilute, Capillary Autoloader: 60 Tubes; Continuous Loading with Auto-Mixing 33 Parameters: CBC: WBC, RBC, Hb, HCT, MCV MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PCT, PDW-SD, PDW-CV, P-LCR, P-LCC, DIFF: Neutrophils % & #, Lymphocytes % & #, Monocytes % & #, Eosinophils % & #, Basophils % & # *ALY % & #, *LIC % & #, *NLR, *Mentzer index and *RDWI *Research use only Principle of Measurement: RBC/PLT/WBC : Electrical Impedance WBC DIFF: Tri-angle Laser Flowcytometry Hb: Cyanide Free Colorimetry MCV: Measured HCT: Calculated Histograms : 3 (RBC/WBC/PLT) Scattergrams : 3 (2D Scattergram), 1 (3D Scattergram) QR Code Reader: For reading sample bar codes & direct input of QC values Sample Volume: Whole Blood: 20 µL Pre- diluted: 20 µL Capillary: 20 µL CBC Mode : 13 µL Linearity Range: WBC : 0 - 300 ( x 103/µL) RBC : 0 - 300 ( x 103/µL) Hb: 0 - 25.0 (g/dL) HCT: 0 - 67 (%) PLT : 0 - 3000 (x 103/µL) Calibrator: ELite H Cal Tri-level Controls: Erba H5 CON L, N, H Open Vial Stability at 2 - 8˚C: 16 Days Throughput: 80 Tests/Hr Quality Control: 500 files with L-J Graph X- Bar Analysis Data Storage: 1,00,000 Results with Graphs Dimension (mm): 650x550x610 Weight (kgs): 59 Reagents: ELite 580 Dil ELite H580Lyse1 ELite H580Lyse2 ELite H580Lyse3 Elite H Clean Interfaces: 4 USB ports ( for connecting external devices including external printers) + 1 LAN Port (HL 7, TCP/IP; LIS connectivity) Operating Environment Temperature: 15-40˚C Humidity: 30-90% Power Requirement: A.C. 100 - 240 V with built-in voltage stabiliser 50/60Hz, 200 VA