product image
Clinical Chemistry

The HumaStar 300SR is the latest member of HUMAN's clinical chemistry systems. Based on the proven hardware and software quality of HumaStar 100/200 it uses the time-tested system reagent kits of HumaStar 600 with perfectly matching methods, calibrators and controls. Throughput: up to 300 tests/h Sample positions: 60 Reagent positions: 40 Prefilled and validated system reagents 2 kit sizes per assay available Open channels: 3 Low water consumption (< 3 l/h) Intuitive and powerful software Multi-language: English, Spanish, French Intuitive and powerful software > Full traceability to reagents (e.g. lot & bottle), calibrations, users and settings > Searchable result database > Onboard and calibration stability monitoring > Automatic outlier detection and unit conversion > Method specific wash options > Designed for touchscreen Flexible system reagent concept > Plug & run HumaStar system reagents > Ready-to-use and available in two kit sizes > Usable for HumaStar 300SR and HumaStar 600 > Prefilled barcoded reagent bottles > Validated assay settings for highest quality > Up to 56 days reagent onboard stability > High quality reagents “Made in Germany” Eco-friendly ProClean 2.0 Technology > Minimal carry-over – dual solution wash station > Low water consumption – less than 3 l/h > Separation and reduction of biohazard waste Easy and efficient operation > Multi-step cuvette wash station for reaction cuvettes > Pre and post dilution for long walk-away time > Bottle cap holder prevents bottle mix-ups and saves time > Quick user- and service-friendly maintenance HUMAN‘s reagent production facility In Magdeburg, Germany we produce our reagents in accordance with the latest quality standards, guaranteeing consistent quality at the highest level. HUMAN Gesellschaft für Biochemica und Diagnostica mbH Max-Planck-Ring 21 · 65205 Wiesbaden · Germany Tel. +49 6122-9988-0 · Fax +49 6122-9988-100 · e-mail: human@human.de · www.human.de Immune Status anti-Streptolysin-O, Complement C3 and C4, CRP, Immunoglobulins IgA, IgG, IgM Liver Panel Albumin, Alkaline Phosphatase, Bilirubin Total and Direct, Cholinesterase, gamma-GT, GOT (ASAT), GPT (ALAT), Total Protein Kidney Panel Calcium, Creatinine, Cystatin-C, Inorganic Phosphorus, Magnesium, Microalbumin, Potassium, Sodium, Urea/BUN, Uric Acid, Urinary Total Protein Arteriosclerosis Cardiac Risk Assessment Cholesterol, HDL-/LDL-Cholesterol, Homocysteine, Triglycerides Anemia Iron, Total Iron Binding Capacity, Transferrin Pancreatic Tests alpha-Amylase, Lipase, Pancreatic Amylase Water & Electrolyte Balance Albumin, Chloride, Potassium, Sodium, Total Protein Cardiac Panel CK-NAC, CK-MB, GOT (ASAT), GPT (ALAT), Homocysteine, LDH Diabetes Glucose, HbA1c, Microalbumin, Triglycerides, Urinary Total Protein Prostata Acid Phosphatase HumaStar 300SR Broad range of clinical chemist

Send Message
product image
Instruments

SV300 Pro is dedicated to simplifying the use of ventilator. With the design in line with clinical needs, SV300 Pro is able to improve the efficiency of clinical operations and maintenances. Frameless Capacitive Screen Frameless designed capacitive screen, more precise touch and easier to clean and disinfect. Comprehensive Comprehensive With comprehensive ventilation modes and decision-supporting tools like SBT, the SV300 Pro manages to fit for the most stringent ICU environment. Intelligent Ventilation Adaptive minute ventilation(AMV TM ) together with IntelliCycle TM enables the ventilator to automatically adjust ventilator settings to reduce the need of frequent ventilator settings adjustment and improve the patient-ventilator synchrony. p69-s3-1 CPRV Ventilation CPRV TM is specially developed for CPR procedure. Quickly access the mode with one-click start, allowing precision ventilation and CO2 monitoring. When used with Mindray unique Electronic Impendence Threshold Device(e-ITD TM ) technology, it can further improve the efficacy of CPR with increase venous return and perfusion. p69-s3-2 Adaptive With a weight no more than 10kg, equipped with powerful turbine and integrated CO₂/SpO₂ monitoring, the SV300 Pro is appropriate for all levels of patient acuity and in all care settings, from the patient's bedside to another point of care with its intra-hospital transport friendly designs.

Send Message
product image
Instruments

The SV300 is a state-of-the-art ventilator that's simple to configure, easy to operate, and versatile in use. It treats pediatric and adult patients with all acuity levels at ICUs and Intermediate Care. Adaptive With its comprehensive list of standard features, including the latest modes of ventilation, the SV300 is appropriate for all levels of patient acuity and in all care settings, from the patient's bedside to transport to another point of care. Comprehensive Equipped with functions that are usually found on intensive care ventilators, the SV300 comes with extensive ventilation modes and unique features that make it a top level ventilator. p84-s4-1 Volumetric CO₂ measurement p84-s4-2 Weaning indicators p84-s4-3 O₂ Therapy p84-s4-4 Intelli Cycle Thanks to the intuitive UI design of the SV300, each function is in logical order so that clinicians do not need to navigate a complex menu. In addition, both the valves and flow sensor support autoclaving. This safety concept is designed to meet the current clinical trends of protecting patients even under the most demanding conditions.

Send Message
product image
Laboratory Usage

Using best-in-class technology, the Mindray CL-6000i is a chemiluminescence immunoassay analyzer with high throughput, high performance and high reliability. Features Throughput: up to 480 tests per hour Measurement principle: enhanced ALP-AMPPD method Reagent carousel: 36 reagent positions with non-stop refrigerating Sample handling: up to 300 samples can be loaded in one batch, sample loading and offloading continuously by sample racks, fast prioritizing STAT samples Sample volume: 5-110 μL Continuously loading of reagents, substrate, cuvettes, wash buffer and waste bags Zero daily maintenance Product Specification Model Name/Number CL-6000i Usage/Application Hospital Brand Mindray Sample Volume Range 5-110 microlitre Throughput up to 480 tests per hour Measurement Principle enhanced ALP-AMPPD method Reagent Carousel 36 reagent positions with non-stop refrigerating Sample Handling up to 300 samples can be loaded in one batch,sample loading and offloading continuously by sample r

Send Message
product image
Clinical Chemistry

TURBOCHEM MAGNA Constant throughput of 300 Tests/hour Discrete random access Bench Top Biochemistry analyzer Independent Probe for Reagents and Sample. Dedicated mixer which enhances faster mixing of reagents and sample High precision results with Low CV% Probe crash prevention with high sensitive liquid level detection of sample/reagents On board laundry with 5 stages of washing Intelligent QC management Bidirectional LIS connectivity Minimal consumable cost for instrument maintenance Remote maintenance, interactive trouble shooting with online application support Constant Throughput of 300 Test/Hour: Guarantees output in any combination Reagent and Sample Tray: Loading more reagent and sample at same time. Intelligent QC Management: Enable QC rules that suit you. Bi-Directional LIS Connectivity: Ensures superior lab process. Specially Designed Mixer: Ensure Homogeneous mixing of reagent and sample.

Send Message
product image
Rapid Test

Buy AccuTest COVID-19 IgG/IgM Rapid Test (Pack of 10 Tests) Online. COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. Intended Use: COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. SUMMARY & TEST DESCRIPTION: COVID-19 [Coronavirus Disease- 2019] is an infectious disease caused by SARS-CoV2 [Severe Acute Respiratory Syndrome coronavirus 2] virus, which is a contagious, novel strain of CoronaVirus that emerged from Wuhan, China in December 2019, which grew as a pandemic threatening human survival across the globe. The virus is thought to be of zoonotic origin and likely to have spread from large seafood and animal markets by human-animal contact in the city of Wuhan, where consumption of such products is in large. The virus causes respiratory infection with symptoms including fatigue, fever, shortness of breath, respiratory failure, renal failure and death. Patients can become infected with SARS-CoV-2 virus by person-person contact (through contact with a contaminated environment or person). The young and old (and other immune-compromised individuals) are most at risk of serious complications; however, approximately 20% of those infected can develop a critical condition. COVID-19 IgG/IgM Rapid Test device utilizes Anti-human IgG and Anti-human IgM antibodies as the capture molecules. COVID-19 Recombinant Antigens-colloidal gold conjugate are used as detection antigen. Intended Use: COVID-19 IgG/IgM Rapid Test Kit is a qualitative immuno chromatographic assay for the detection of IgG & IgM antibodies produced against COVID-19 virus in human whole blood/Serum/ Plasma. COVID-19 IgG/IgM Rapid Test Kit is only intended for initial screening and reactive samples should be confirmed by a supplemental assay. SUMMARY & TEST DESCRIPTION: COVID-19 [Coronavirus Disease- 2019] is an infectious disease caused by SARS-CoV2 [Severe Acute Respiratory Syndrome coronavirus 2] virus, which is a contagious, novel strain of CoronaVirus that emerged from Wuhan, China in December 2019, which grew as a pandemic threatening human survival across the globe. The virus is thought to be of zoonotic origin and likely to have spread from large seafood and animal markets by human-animal contact in the city of Wuhan, where consumption of such products is in large. The virus causes respiratory infection with symptoms including fatigue, fever, shortness of breath, respiratory failure, renal failure and death. Patients can become infected with SARS-CoV-2 virus by person-person contact (through contact with a contaminated environment or person). The young and old (and other immune-compromised individuals) are most at risk of serious complications; however, approximately 20% of those infected can develop a critical condition. COVID-19 IgG/IgM Rapid Test device utilizes Anti-human IgG and Anti-human IgM antibodies as the capture molecules. COVID-19 Recombinant Antigens-colloidal gold conjugate are used as detection antigen. PRECAUTIONS & WARNING 1. This package insert must be read completely before performing thetest. Failuretofollow directions in insert may yield inaccurate test results. 2. Test results should be read between 10 and 15 minutes after aspecimenisapplied to the sample well. Results read after 20 minutes may giveerroneousresults.3. Do not open the sealed pouch until you are ready to conduct theassay.Onceopened, the cassettes should be used immediately. 4. Do not use expired devices. 5. Bring all reagents to room temperature (15-30°C) prior to use. 6. Do not mix components from different kits. Use only the buffer suppliedalongwith the kit. 7. Wear protective clothing and disposable gloves while handling thekit reagentsand clinical specimens. Wash hands thoroughly after performing thetest. 8. Do not smoke, drink, or eat in areas where specimens or kit reagents arebeinghandled. 9. Dispose of all specimens and materials used to performthe test as biohazardouswaste. 10. Handle the negative and positive controls in the same manner as patientspecimens for operator protection. 11. Do not perform the test in a room with strong air flow, i.e. an electricfanorstrong air-conditioning. 12. Do not touch result window. 13. Use only for in-vitro diagnostic purpose.

Send Message
product image
Rapid Test

Buy AccuTest Vitamin D Rapid Card Test (10 Tests) Online from Accurex. The Vitamin D test kit consists of 25 AccuTest Vitamin D individually packed test, devices in foil pouches, 25 pipettes for collecting 10 ul of whole blood, 25 lancets, 1 Buffer Vial (Buffer 5 mL) with stabilizers and, thimerosal, 1 Package Insert. Vitamin D Fast test kit is a rapid chromatographic immunoassay for the semi quantitative detection of Vitamin D levels in human blood/serum. This Vitamin D test provides a preliminary screening test result. INTENDED USE AccuTest Vitamin D is a rapid chromatographic immunoassay for the semi quantitative detection of Vitamin D levels in human blood/serum. This assay provides only a preliminary screening test result. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. The performance characteristics of this assay have not been established in a pediatric population. PRINCIPLE AccuTest Vitamin D is based on the principle of a competitive enzyme immunoassay. The assay is based on the competition for 25-OH Vitamin D present in blood/serum sample and Vitamin D present on the test line for fixed number of antibody-gold conjugate. Depending upon the concentration of Vitamin D in blood/serum, there will be free antibody-gold conjugate molecules that will bind to Vitamin D on the test strip and will show a colored line in the test line zone. A control line is present in the test window to work as procedural control. PRECAUTIONS 1. For in vitro diagnostic use only. 2. The test is designed for use with human blood/serum only. 3. Reagents must be at room temperature (8⁰C – 30 ⁰C). 4. Do not use if test device packaging is open or damaged. 5. Do not use the product beyond expiration date. 6. Handle all specimens as potentially infectious. Proper handling and disposal methods should be used according to good laboratory practices. 7. Read test results for 10 minutes as required. Results may deteriorate and may not be consistent after 10 minutes. 8. In order to avoid variable results, mix the blood sample thoroughly. 9. A serum sample subjected to repeated freeze thaw cycles may give variable results Direction for Use PROCEDURE 1. Remove the cassette from the sealed pouch and place it on a hard flat surface with the view window facing up (use the cassette as soon as possible). 2. Using a micropipette, add 10 µl of whole blood or 5ul of serum sample directly into the rectangular specimen well (marked with Red drop) of the cassette. 3. Add 3 full drops of Buffer into the square buffer well of the cassette (Do not move the cassette after addition of buffer). 4. Let the cassette sit for 10 minutes and read your results immediately. Results may deteriorate after the 10 minute mark. Other Info STORAGE AND STABILITY The test device should be stored at 8 ⁰C – 30 ⁰C and will be stable until the expiration date stated on the package. The product is humidity sensitive and should be used immediately after being open. INTERPRETATION OF RESULTS Match the color of the test line with the chart provided.