Jaipur
+918529833535

'3 levels levy jenning qc graphs display'

Items tagged with '3 levels levy jenning qc graphs display'

product image
Clinical Chemistry

Product Description: An advanced & versatile semi automated analyzer for all Clinical chemistry, Electrolytes, Immunoturbidimetric assays and Coagulation test Product Features: Semi automated analyzer 56 direct access keys Temperature selection for 20oC - 40oC in steps of 1oC 5 reporting formats Online display of reaction curve Result recalculation Three levels of quality control with Levy Jennings plot 5 reporting formats USB port interface for PC & printer Product Applications: Entire range of Clinical chemistry, Electrolytes, Immunoturbidimetric assays and Coagulation Optical Module: Static photometer with photometric range (340-670) 8 Interference filters 340, 405, 450, 505, 546, 578, 600 and 670 n.m. Silicon photodiode detectors Photometric range from 0 to 3.0 OD Quartz Halogen lamp of 12V, 20W Measuring Module: Unique Triple cuvette system 18 µl Flow cell 10 mm Square cuvette 6 mm Round glass tube with adaptor Peltier temperature control: 20°C-40°C in steps of 1°C Peristaltic Pump Minimum aspiration volume 200 µl Analysis Modes 1-point linear Rate A non-linear 2-point linear 1-point sample blank linear 1-point non-linear 1-point sample blank non-linear 2-point non-linear Absorbance Rate A linear Coagulation Memory: 200 User defined test programs 1000 test result Reagent Blank 3 Levels of QC Result Recall: Collated Reports by Date, ID, Date & ID Test & Date wise Patient Demographics Built-in QC: Daily and monthly monitoring for 3 Levels Levy-Jenning QC graphs Display: High resolution graphics LCD with backlight. View Area: 120 x 92 mm Keyboard: 41 Multifunction Keys and 6 dynamic keys Printer: In built high resolution graphic thermal printer Interface: USB connectivity to PC Direct printer connectivity through USB port Port for External keyboard Power: External Universal SMPS adapter 18V DC, 70W, 115/230V AC (± 10%), 50/60 Hz Size: (mm): 205 (H) x 450 (W) x 300(D) Weight: Approx. 7 Kgs. Optional Accessories: External 16 Position Dry Block Incubator

Send Message
product image
Clinical Chemistry

The Autochem Xact Pro is a Fully Automatic Random Access Clinical Chemistry Analyzer. It is a compact, benchtop analyser with throughput up to 200 tests per hour. First-in-Class On-board Warm-water Laundry System Probe with Collision-Protection System Multi function Probe which works as mixer also Probe with Capacitance based liquid level sensor Robust Multi-functional Software Intelligent" Mixing Arm Removable & flexible Sample - Reagent Disc with 40 Open position for reagent & samples respectively. DESIGNED FOR UNINTERRUPTED WORK FLOW OTHER FEATURES ROBUST MULTI-FUNCTIONAL SOFTWARE Probe with Collision-Protection System Both horizontal and vertical collision protection ensures that system re-starts testing after any unwanted physical intervention. This prevents wastage of reagents, saves test time and increases life of probe Multi functional Probe Probe has flexibility to work even as a mixer in case in-built mixer does not work Probe with Capacitance based liquid level sensor Probe with liquid level sensor checks and indicates the presence of adequate sample or reagent in the container before starting testing process. Thus prevents unwanted interruptions in testing process “Intelligent” Mixing Arm User defined, variable three level mixing speed ensure thorough mixing Accurate performance of regular and immunoturbidimetric assays Independent cleaning station for mixer which prevents carry-over ensuring high precision Removable & flexible Sample – Reagent Disc 40 Open position for reagent & samples respectively Facility to use primary & variable sample cup as well as non fixed position for Sample, Control, Calibrator & STAT samples Two bottle sizes of 18 mL or 5 mL with unique design to reduce reagent dead volume Optional internal Reagent & Sample barcode reader makes the operation user friendly & ensure correct result reporting Reaction tray 60 reusable plastic reaction cuvettes which is also scanned before performing the test which means less recurring cost without compromising on quality. To assure precise results Individual replacement of cuvette offer lower consumable cost REFLEX Testing Functionality Allows user to program Low & High panic value for a particular test which triggers auto-testing of assigned tests which ensures faster and comprehensive reporting Dynamic & Real-time display of Test Running Status for quicker decision making Running status of reagent tray, Sample tray & reaction tray Real-time monitoring of Reaction curve On board inventory management Real-time monitoring of reagent residual volume saves reagent cost & time In-built full QC Program Provision to run 3 levels of control with Levey Jennings graph which gives confidence in reporting with multiple rules (1SD, 2SD and 3SD) Reagent, Calibrator & Control lot monitoring User friendly Bi-Directional LIS Interface

Send Message
product image
Clinical Chemistry

Best Semi Automatic Biochemistry Analyzer AT Smart from Accurex. AT SMART is a Biochemistry/Clinical Analyzer with a user-friendly and the human interface is via touch screen. It measures the optical densities of samples & calculates the sample concentration which are used for biochemical investigation. This Biochemistry Machine operates from near UV to visible range. Semi Auto Analyzer AT SMART is CE certified and has undergone rigors testing before being delivered to customers. About •SMART MAINTENANCE •SMART LIS •SMART INVENTORY MANAGEMENT REDUCED ERRORS: IT allows for the accurate collection of data, automated workflows & minimized waste. SAVES TIME: Patient monitoring can be done in real-time, saves engineers visiting time. BETTER PATIENT EXPERIENCE: A connected laboratory system creates an environment that meets each patient’s needs. INSTRUMENT BREAKDOWN MANAGEMENT: Real-time data helps to monitor instrument performance. ONLINE REACTION CURVES: • Real time reaction curve with special • Flagging gives confidence in patient reports. INTELLECTUAL SOFTWARE: • User friendly Device. • 150 Direct access test keys gives freedom to select parameters easily. • Availability of different assay modes. DRY BATH INCUBATOR: • Dry bath incubator with 12 test tube positions • Mini size with 15 minutes start up time FEATURES: •Remote access & monitoring via Internet •150 test parameters •Built-in thermal printer to print results, enzymatic curves and standard calibration curves •Large graphic display with real time graph display for enzymatic reaction •Touch screen interface with dynamic test access key SPECIFICATIONS: Methodology- • Absorbance • Endpoint with standard, factor, sample blank & diffrential • Two-point (fixed time) and multi point kinetics • Multi standard calibration • Mono or bi-chromatic reading • Turbidimetry Optical System- • Principle: photometry • Range of measurement: 0.0-3.0A • Spectral range selection: Automatic via filter wheel • Filters: 340, 405, 505, 546, 578 and 630 nm plus two free position • Bandwidth:10nm (+/- 2nm) • Light source: Life Long Halogen lamp • Blanking: Automatic • Detector: Silicon Photodiode Photometer- • Peltier regulated 25ºC, 30ºC and 37ºC • Flow cell of 18 µ L • Continuous flow system with peristaltic pump • Programmable Sipping Volume Memory- • 150+ User Defined Test Programs • 1000 test results in instrument memory and unlimited test resultresult storage via cloud • Reagent Blank • 2 Level of QC Quality Control- • Levy-Jennings chart using westgard’s rules • 30 Normal and abnormal QC values for selected test User Interface- • Graphic LCD back Lit 240×64 pixels • Touch Screen input • Data port and cloud connectivity • Type : Graphic thermal printer Power & Dimensions- • Voltage : 220 V • Frequency : 50 Hz • Maximum power : < 150 VA • Maximum relative humidity : 75% • Compact form factor • Weight: < 6kgs Safety Information Precautions • Instrument should be operated only by authorised or trained personnel • For any reasons, unauthorised personnel should not be engaged for servicing or removing the cabinet • Power source should be regulated either by voltage stabilizer or regulated power back up (UPS). If inverter is been used, please ensure there exists a voltage stabilizer • Reagents recommended by the company to be preferably used • Flow cell needs to be rinsed regularly with the company recommended flow cell cleaning solution • User is requested not to use any other pointing devices other than being supplied by company while operating touch screen • The operating environment should be clean and protected from direct sunlight • During the day at the end of the work, it should be ensured that flow cell is always filled with distilled water • During transport / longer duration of shut down, th Direction for Use Please ensure that the power source is properly grounded and voltage between Line and Ground is less than 2V AC – 5V AC. • Please ensure that the instrument is placed on a firm table, clean environment, and sufficient ventilation space. • Switch On the instrument. • Instrument will run its own internal diagnostic routines, to ensure proper working of critical functions. • Allow the instrument to stabilize for 10 minutes. • During the stabilization time, please wash the flow cell with cleaning solution and distilled water for at least two times. • During shut down, ensure that the flow cell is cleaned with flow cell cleaning solution and rinsed thoroughly using distilled water. • For overnight shutdown, please ensure flow cell is filled with distilled water. • Cover the instrument with the given dust cover Other Info GENERAL INFORMATION While installing and setting up the instrument, few safety warnings and general precautions described in the further sections must be observed. A. Power Supply : • Power source should be grounded and have either servo stabilizer or regulated power back up • Power cord should be CE , CSA and UL marked • Voltage : 115 – 230 Volts ± 10% 50 – 60 Hz • Grounding: Make sure that electrical power source is properly grounded.

Send Message
product image
Hematology

Buy the Best Automated Hematology Analyzers – Acculab CBC 360 Neo. This Hematology Analyser Machine is Truly Automated for self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance. CBC 360 Neo is 3 part hematology analyzer from Accurex & is Automated for Walk-away Operations. Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Automation for Walk-away Operation: Auto Self-check : Automatic aspiration of reagents & rinsing of tubings on startup Auto Blank : Background test is run automatically on startup Auto Print : Automatic printing of report with / without histogram Auto Sleep : Dormancy status is entered after a set period of non-operation Auto Alarms : Audio / visual alarms in case of system errors & abnormal results Auto Clean : Automatic rinsing options available to maintain the system Dual Chamber: Measurement of RBC / platelets & WBC / HGB in different chambers ensure accurate counting in a short time. The micro-aperture sizes of both the chambers are well designed to avoid error due to cell misclassification Specifications: Measurement principle: Electrical resistance for counting RBC, WBC & Platelets Colorimetric estimation of HGB at 540 nm Parameters: WBC, LY, MO, GR, LY%, MO%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR Throughput: 60 samples/hour Micro-aperture: WBC : 100 um RBC / PLT : 68 um Sample type: Whole blood or pre-diluted sample Sample volume: Whole blood (venous blood) : 10 ul Chamber: Pre-diluent (capillary blood) : 20 ul, Pre-diluent (capillary blood) : 20 ul Reagents: Dual chamber : RBC / Platelets & WBC / HGB Quality control: 4 QC options : L-J, X-B, X-R & X QC, Graphs plotted with 31 data points Data memory: Upto 100,000 (with histogram) Display: 10.4 inch LCD with 640 x 480 resolution Printer: Built-in thermal printer Interface: Support RS-232C, standard network port and USB; keyboard and mouse Operating environment: Temperature : 15˚C – 35˚C, Humidity : 85% RH Electrical specification: Voltage : AC 110V/230V 23V Frequency : 50/60 Hz, Power : 180W Fuse specification : 250V/3A Dimensions / Weight: 670 x 515 x 640 mm / 27.5 kgs Specification Acculab CBC 360 Neo – Fully Automated Hematology Analyzer Features: 3-part differentiation of WBC Automated for — self-checking, background test, calibration, sampling, dilution, mixing, printing, dormancy, alarms, cleaning and maintenance High processing speed : 60 samples/hour Multi-parameter estimation : 20 parameters categorized according to corpuscle type for easy reporting Direct command keys for Mode, Prime, Flush, Drain & Record / Print for faster operation Run / Standby indicator lights denote the analyzer status i.e. test is being run or analyser is ready to test Whole blood/ Pre-diluent indicator lights denote the sample type in use i.e. whole blood/ pre-diluent Dual sample mode with low sample volume: Whole blood (venous) mode : 10 ul; pre-diluent (capillary) mode : 20 ul Audio alarm indication for abnormal findings or system errors 4 QC methods : L-J, X-B, X-R & X QC Comprehensive QC graphs with 31 data points for each parameter Internal & external probe cleaning facility Dormancy mode available to reduce power consumption Memory : 100,000 (with histogram) Safety Information • Large 10.4 inch single screen color display of all 21 parameters and 3 histograms • Sequential arrangement of WBC, RBC & PLT parameters for convenient reporing •Easy to understand & icon-based arrangement of menu for fast and convenient testing Direction for Use • WBC Histogram: R1, R2, R3, R4 & RM indications on histogram show specific abnormalities in the histogram & the probable causes • Platelet Histogram: PM indication is given when the boundary between PLT & RBC is ill-defined thus avoiding misclassification Other Info High voltage cautery function is useful in disintegrating obstinate protein or serum clog in the tubing

Send Message
product image
Hemostasis Analyzer

Product Description: It’s a modern and advanced analyzer in Hemostasis. This single channel coagulation analyzer redefines the benefits in its class Erba. ECL 105 can perform PT, APTT, Fibrinogen, Thrombin Time, All Factiors, Lupus and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant performed using Light scatter principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting testCuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests. Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 105 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centres It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc Key Specifications: Single channel semi-automated hemostasis system It can analyze 1 test at a time Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second position of assay preparation/incubation during the analysis of the current one, using preparation line option Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 216 x 205 x 75 mm Weight : ~1 kg Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply : 100-240 VAC and 50/60 Hz Power Consumption : 45 Watts In-Rush Power : 150 VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored Results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 1000 results for QC determinations Up to 1000 results for patients New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pen drive. Regular backup and file purging is recommended from the USB pen drive to insure rapid operations. USB pen drive, FAT32 formatted

Send Message
product image
Hemostasis Analyzer

Product Description: It’s an advanced analyzer for Complete Hemostasis. This four channel coagulation analyzer redefines the benefits in its class. Erba ECL 412, can perform PT, APTT, Fibrinogen, Thrombin Time , All Factors, Lupus , Protein S, Protein C , Antithrombin III and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant, Protein S performed using Light scatter principle. Protein C, Antithrombin III done by Chromogenic Principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting test Cuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 412 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centers It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc General Specifications: 4 channel semi-automated hemostasis instrument It can perform 4 simultaneous tests of the same parameter Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second row of assay preparation/incubation during the analysis of the current line, using preparation line option It can run assays in single or duplicate (programmable per assay) Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Chromogenic (colorimetry at 405nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 300 x 290 x 90 mm Weight : 3 kgs Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply: 100-240 VAC and 50/60 Hz Power Consumption: 45 Watts In-Rush Power: 150VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control names total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 600 results for QC determinations (run in duplicate) Up to 900 results for patients (run in duplicate) New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pendrive. Regular backup and file purging is recommended from the USB pendrive to insure rapid operations. (We recommend at least a monthly purge from a computer to back up and remove CH files) USB pendrive , FAT32 formatted

Send Message
product image
Hematology

A Truly Automated Walkaway ESR Analyzer for Midsize labs (Meets CLSI and ICSH Guidelines) Product Features: Gold Standard Method -Measures all three phases of sedimentation as per Westergren method Dry Technology - No sample & reagent consumption, no waste generation Faster TAT - Throughput of 60 samples/hr Zero consumption cost by using EDTA tubes HCT correction feature eliminates manual correction in Anaemic samples Temperature correction at 18° ensures reliable results No additional cost of Calibration Analyzer Product Code Product Name Pack size ESL 30 122020 SMART CARD 2500 1x 2500 ESL 30 122021 SMART CARD 5000 1x 5000 ype of Sample : EDTA Sample Volume : > 1.5 ml Display : TFT high resolution 640 * 480 dots with LED Backlight Result Cycle Time : < 25 min Measuring Range : 0-140 mm/hr Touch screen : 5.7 inch resistive TFT high resolution Temperature Correction : At 18 Degree HCT Correction : HCT Correction facility available for Anaemic samples QC : Inbuilt Quality Control program with LJ Graphs Quality Control Level : 3 Level QC with LJ Graph QC Data Storage : 250 QC results Sample position : 30 sample position Throughput : 60 samples per hour Sample Consumption : No Type of Mode : Continuous mode STAT Facility : Available Calibration Requirement : No Mixer : Inbuilt Mixer Printer : Inbuilt Printer Barcode reader : Inbuilt Barcode reader Data Storage : 5000 results Operating Temperature : 20 - 30 Degree Celsius Storage Temperature : 15 - 35 Degree Celsius Relative Humidity : Max. 80% RH Power Adapter external : 240V DC , 90W Main supply : 100V-240V AC, 50/60 Hz (input for power adapter ) Dimension (mm) : 550(L) x 500 (W) x 395 (H) Weight : 20 kg (Approx )

Send Message
product image
Hematology

The BC-3600 Hematology analyzer features closed tube sampling via a single push button. A built-in large 10.4 inch color touchscreen allows maximum visibility. Hemoglobin analysis is performed using cyanide-free reagent. The analyzer processes up to 60 samples per hour and stores up to 40,000 results with histograms. The barcode reader and optional LIS connectivity enable seamless sample data transmission. Nearly all scheduled maintenance procedures are automated by touch buttons. The intuitive software enhances workflow efficiency and provides operators with a pleasant user experience. Key Features CBC plus 3-part differential, 16 parameters + 3 histograms 60 samples per hour, 1 min per CBC Closed tube sampling, minimize operational biohazard Built In diluent dispenser for predilution mode All-in-one CBC result screen display; results at a glance Touch button maintenance procedures One maintenance reagent only – probe cleaner Storage capacity of 40,000 results with histograms Uploadable QC files; ensure accuracy and time efficiency Parameters WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT,MCV, MCH, MCHC, RDW,PLT, MPV and histograms for WBC, RBC, PLT Principles Electrical impedance method for cell counting and Cyanide - free for hemoglobin Sample Volume Prediluted 20µL Whole Blood 21µL Carryover WBC/RBC/HGB≤0.5% PLT≤1.0% Connectivity 4 USB ports (for external printer, software upgrade, barcode reader,keyboard and mouse), LAN port (1), RS232 (1) Printout Thermal recorder, 50mm width paper, various printout formats, external printer (optional) Product Specification Brand Mindray Differential Type 3-Part Model Name/Number BC 3600 Display Type Large color touch screen Resolution 800x600 Usage/Application Hospital Throughput 60 samples per hour Power Supply AC 100-240V,50/60 +-1Hz Weight 62 lbs Dimension 16 in(W) x 18 in(H) x 18 in(D) Humidity 30%-85% Temperature 15 ~30 Deg C Minimum Order Quantity 1

Send Message
product image
Hematology

Product Description AutoCell Plus 3 Part WBC Differential Automated Hematology Analyzer Large Touch Screen Display Easy analysis of patient data on single screen ensuring efficient work-flow 10.4" color touch-screen Data + Hitogram Based Result 20 parameters numerical data 8 3 histo grams Results are displayed as group of "data + histogram" for each parameter enabling easier correlation. Dual Sample Mode Ft Small Sample Volume Just 9 pL whole blood required for test - Very useful for pediatric & geriatric patients where sample collection may be very difficult 20 pL Pre-dilution mode - Automatic dilution in case of capillary sample by analyser which minimizes manual dilution-related errors. Other Important Features: Direct access Clog removal key saves time for user by not needing to come back to main menu. Comprehensive built-in QC program for up to 10 lots with X -R, X B, X D CV value. Flexibility of dual calibration (Automatic 8 Manual calibration)allows user to calibrate the instrument according to his need to ensure the accuracy of measurements (results) Dual chamber for WBC Et RBC makes faster test results with more accurate & avoids cross-contamination Reagent depletion alarm for Lyse, Cleanser and Diluent, as optional function (Liquid Sensors) 10, 000 test results with histogram to meet all requirements Auto background measurement during start-up for ensuring trouble-free operation Internal thermal printer or facility to connect optional external printer RS232 interface & PC connectivity

Send Message

Still searching for
3 levels levy jenning qc graphs display?