Jaipur
+918529833535

'2 ghz mode open'

Items tagged with '2 ghz mode open'

product image
Clinical Chemistry

Product Specification Model Name/Number HumaStar 200 Brand Human Automation Fully Automatic Display Digital Dimensions 69 x 76 x 52 cm (WxDxH) Frequency 50/60 Hz Voltage 220-240 or 110-120 Vac Temperature 16-30 Degree C Throughput Up to 200 t/h throughput Weight 51 kg Reaction volume 210-350 il Wash station 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Languages English, French, Spanish Software (other languages can be added) Humidity < 80 % non-condensing Data External computer required (Pentium IV, 2 GHz Mode Open, random-access, STAT Product Description Product Detail : Unique Random-Access Analyzers for Small to Medium Size Laboratories Unique design Unique software architecture Unique features Analysis Endpoint (bichromatic), Differential endpoint (with sample blank), Fixed time, Kinetic (bichromatic) Multi-standard (up to 8), factor, linear, non linear (cubic-spline, poly-linear and logit-log four parameters) Samples Removable sample tray 60 positions: primary tubes 12–12.5x100 mm and 10 mm cups Optional: sample tray for 20 primary tubes 12–16x100 mm and 20 cups 3.5 ml Sample volume: 2–300 µl Internal barcode reader Automatic pre- and post-dilution Test profiles and replicates Reagents Removable reagent tray 30 reagent / diluent positions 50 and 20 ml bottles, adapter for tubes and cups Reagent volumes: 5–350 µl Refrigeration to ~9 Degree C below ambient (at bottom of bottle) Substrates, Enzymatic, Turbidimetric Reaction Reaction volume: 210–350 µl 80 reusable Bionex® cuvettes 6 mm optical path Heat transfer by air Pipetting Needle shock detector Capacitive liquid level detector Wash station 8-step cuvette wash station Systemic and special washing solution HumaStar 200: 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Optical system 9 discrete wavelengths (340, 405, 505, 546, 578, 600, 650, 700 nm, one free position) Band pass: +/– 5 nm Photometric linearity: 0–2.5 Abs Stability: <1 % drift per day Management 20 GB HDD, 512 MB RAM, CD/R, USB) Windows 7® with .NET framework 4.0 English, French, Spanish OS recommended Core i3TM or dedicated graphic card recommended Minimum 900 dots resolution Designed for touch screen (1280x1024 pixel) LIS: Bi-directional, polling mode, ASTM, ethernet Printouts By patient, single test, complete sample, work sheet, method and QCs, calibration curves, kinetics, continuous printing

Send Message
product image
Hematology

At Mindray we pride ourselves on our dedication and experience in developing better solutions for small labs. Our new line of 3-part hematology analyzers is the culmination of that effort. Compact yet powerful, full featured yet affordable, the BC-20s is what a 3-part analyzer should be. Features CBC+3-DIFF, 19 parameters+3 histograms Throughput:40 samples per hour Intuitive operation system with 8.4 inch TFT touch screen Open vial sampling 200,000 results storage with histograms Original QC, calibrators and reagents Product Specification Instrument Name Haematology Analyzer Model Name/Number BC20s Usage/Application Laboratory Brand Mindray Automation Fully Automatic Operation Mode Fully Automatic

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Estradiol (E2) Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters is for quantitative measurement of Estradiol (E2) in human whole blood, serum or plasma. The test is used as an aid to the evaluation of ovarian diseases. STORAGE AND STABILITY 1. Store the test kit at 4~30℃ up to the expiration date. 2. If removed from refrigerator, allow the test for 30 minutes to return to room temperature before testing. 3. Do not remove the cassette from the pouch until ready to use. The Test cassette should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ β2-MG Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of β2-MG (Beta-2-Microglobulin) concentration in human plasma, serum or whole blood. The test is used as an aid for the diagnosis of renal disease. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ Lp-PLA2 Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Lp-PLA2 in human serum, plasma or whole blood. The test is used as an aid to the assessment of the coronary heart disease (CHD) and ischemic stroke. STORAGE AND STABILITY 1. Store the test kit at 4℃-30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
Hematology

At Mindray, we pride ourselves on our dedication and experience in developing better solutions for small labs. Our new 3-part hematology analyzer is the culmination of that effort. It provides small labs with more confidence in results and less turnaround time. Features CBC+3-DIFF, 20 parameters +3 Histograms Throughput: up to 30 samples per hour 8.4 inch TFT touch screen Only three reagents needed Open vial sampling Large storage capacity: up to 50,000 samples Original QC, calibrators and reagents Automation Fully Automatic Instrument Name Hematology Analyzer Brand Mindray Differential Type 2-Part Usage/Application Clinical Number Of Chambers 1 Model Name/Number BC-10 Power Source Electric Voltage 240 V Frequency 50 Hz

Send Message
product image
Hematology

At Mindray, we pride ourselves on our dedication and experience in developing better solutions for small labs. Our new 3-part hematology analyzer is the culmination of that effort. It provides small labs with more confidence in results and less turnaround time. Features CBC+3-DIFF, 21 parameters+3 Histograms Throughput: up to 60 samples per hour 10.4 inch TFT touch screen Only three reagents needed Open vial sampling Large storage capacity: up to 400,000 samples Original QC, calibrators and reagents Product Specification Automation Fully Automatic Instrument Name Hematology Analyzer Brand Mindray Usage/Application Clinical Differential Type 3-Part Number Of Chambers 2 Number Of Parameters LYM Model Name/Number BC-30s User Input Touch Voltage 240 V Frequency 50 Hz Power Source Electric