Jaipur
+918529833535

'150 va'

Items tagged with '150 va'

product image
Laboratory Usage

Soil moisture meter TDR 150 Portable soil moisture meter allows you to obtain readings on the go at the press of a button. Variable rod length options provide soil moisture measurements at your ideal root zone. With new enhancements, the TDR 150 provides significant improvements in performance and measurement accuracy for optimal turf and soil environments. Increased accuracy of soil moisture (Volumetric Water Content) Measures EC (Electrical Conductivity) Measures Turf Surface Temperature Option to add on Bluetooth and GPS Data logger records approximately 50,000 measurements Industry exclusive backlit display Ergonomic handle Data collected with USB flash drive No PC interface needed Powered by AA lithium batteries Ideal for measuring containers on benches Optional IR Temp sensor to measure canopy TDR 150 SPECIFICATIONS Measurement Principle: Time - domain measurement methods Measurement Units: Percent Volumetric Water Content (VWC) Resolution: 0.1% VWC Accuracy: +- 3.0% VWC with Electrical Conductivity (EC) < 2 mS/cm Range: 0% to saturation (Saturation up to about 50% volumetric water depending on soil type) Battery/Life: 4 AA lithium batteries; approximately 100,000 readings without backlight Data Logger: 50,000 measurements EC Range: 0 to 5 mS/cm, Resolution: 0.01 mS/cm, Accuracy: +/- 0.1 mS/cm Temperature Range: -30°C to 60°C, Resolution: 0.1°, Accuracy: +/- 1°C

Send Message
product image
Hemostasis Analyzer

Product Description: It’s a modern and advanced analyzer in Hemostasis. This single channel coagulation analyzer redefines the benefits in its class Erba. ECL 105 can perform PT, APTT, Fibrinogen, Thrombin Time, All Factiors, Lupus and DDimer. Product Features: Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant performed using Light scatter principle Tests like D Dimer performed using Immuno-turbidimetry principle Interactive touch screen interface Clotting Graph provides details of the clotting testCuvette and reagent management software Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors Temperature stability at 37 degree C to perform the tests. Low Reagent Consumption USB Connectivity CE mark Product Applications: ECL 105 has uses in various routine IVD labs for doing routine PT and aPTT It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII It is used as Standby to bigger systems, in accredited centres It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc Key Specifications: Single channel semi-automated hemostasis system It can analyze 1 test at a time Sample id can be 14 digits alphanumeric, with progressive id or custom id options It is also possible to have a second position of assay preparation/incubation during the analysis of the current one, using preparation line option Optically detects and automatically moves to the next assay steps and auto starts the measurements Tests principles: Clotting (scattered light at 640nm) Immuno-turbidimetric (turbidimetry at 800nm) Dimensions / Weight: Dimension : 216 x 205 x 75 mm Weight : ~1 kg Environmental requirements: Operating Temperature : 17-32°C Humidity: Max. 80% Relative Humidity, non-condensing Power: Power Supply : 100-240 VAC and 50/60 Hz Power Consumption : 45 Watts In-Rush Power : 150 VA or less Calibrations: Up to 6 calibration levels per assay Storage of the active calibration curve Quality Controls: Up to 12 different control total can be assigned to any given assay Automatic Levey-Jennings plotting Automatic statistics calculation Storage of Quality Control results Stored Results: Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations Up to 1000 results for QC determinations Up to 1000 results for patients New results automatically replace the oldest results of the appropriate category past the maximum storage allowance Reaction curves are exclusively stored on the external USB pen drive. Regular backup and file purging is recommended from the USB pen drive to insure rapid operations. USB pen drive, FAT32 formatted

Send Message
product image
Rapid Test

Intended Use Advantage Dengue NS1 Ag card is a rapid solid phase Immuno-chromatographic test for the qualitative detection of Dengue NS1 Antigen in Human serum /Plasma.This test is for in vitro diagnostic use only and is intended as an aid in the earlier diagnosis of Dengue Infection. Salient Features Rapid test based on lateral flow technique. Detection of Dengue in the seronegative stage i.e. from Day 1 of fever. Detection of all the 4 Dengue serotypes (DEN-1, DEN-2, DEN-3 and DEN-4). Results with in 20 minutes Longer shelf life : 30 months at 2-30°C. Convenient pack size : 25 tests Sensitivity-96% and Specificity- 98%

Send Message
product image
Rapid Test

Intended Use Advantage Leptospira IgM & IgG card is visual, rapid, sensitive and qualitative immunoassay for the detection of Leptospira specific IgM & IgG antibodies in human serum or plasma. Salient Features Rapid qualitative test for differential detection of Leptospira specific IgM and IgG Antibodies in Human serum/plasma. One step test procedure, add sample & read results Infection free see through device. Results with in 20 minutes. Shelf life of 30 months at 2-30°C. Excellent Sensitivity- 99 % and Excellent Specificity- 99.5%

Send Message
product image
Rapid Test

Intended Use Advantage Typhi IgM & IgG Card is a rapid solid phase immuno-chromatographic test for the qualitative differential and simultaneous detection of salmonella typhi (S. typhi) IgM and IgG antibodies in human serum / plasma. This test is for in vitro diagnostic use only and is intended as an aid in the earlier diagnosis of typhoid infection and in the determination of recent and past infection. Salient Features Rapid qualitative test for differential detection of Salmonella typhi (S.typhi) IgM and IgG Antibodies in Human Serum / Plasma Determination of both recent and past infection Results within 20 minutes Bio-hazard free, fully covered, see-through Device Simple & Easy to use Test Procedure No Instruments required Long Shelf Life: 30 months at 2-30ºC Convenient Pack size: 50 Tests

Send Message
product image
Rapid Test

Intended Use Advantage Malaria Card is a visual, rapid and sensitive immunoassay for the qualitative differential detection of P.falciparum (HRP-2) and P.vivax (pLDH) malaria antigen in human blood only. Salient Features Rapid, visual antigen based test for detecting infection with P.falciparum (HRP-2) & P.vivax (pLDH) malaria parasite in whole blood. Excellent Sensitivity & Specificity. See through Device for easy result interpretation. Longer shelf life of 30 months at 4-30° C. Easy to interpret colour bands Results within 20 minutes.

Send Message
product image
Rapid Test

Intended Use Advantage PAN Malaria Card is a rapid, visual and sensitive immunoassay for the qualitative diagnosis of all four Plasmodium Species (P.falciparum/P.vivax/P.malariae/P.ovale) based on pLDH antigen in human whole blood only. Salient Features Detects infection with Plasmodium species(P.falciparum/P.vivax/P.malariae/P.ovale) Excellent Sensitivity & Specificity as per WHO Malaria RDTs Evaluation. See through Device for easy result interpretation. Longer shelf life -30 months, storage at 4-30° C. Results within 20 minutes.

Send Message

Still searching for