Jaipur
+918529833535

'14 ph'

Items tagged with '14 ph'

product image
P H Meter

From the market leader of testers comes the EcoTestr pH 1 & pH 2 – a new range of value-for-money, quality pH tester series designed for fuss-free pH measurements. Accurate, and easy to use, these testers are ideal for quick pH checks in hydroponic gardening, aquaculture, agriculture, pools, simple lab work and other water/wasterwater applications. 0.0 to 14.0 full pH range Auto-calibration & auto-buffer recognition IP67 waterproof – tester floats on water for easy retrieval Long sensor life – no need to change sensors Click-lock battery compartment requires no tools for battery replacements Hold function freezes reading temporarily for ease of recording Sensor protective cap that doubles up as a container for samples or calibration solution

Send Message
product image
P H Meter

Type of PH Meter Table-Top, Portable Type Digital, Analog pH Range 0 - 14 Is It Water Proof Water Proof Color White Backed by a team of skilled professionals, we are highly engaged in manufacturing and supplying a wide array of Portable PH Meter. Offered Ph meter is developed utilizing supreme class components and leading technology in adherence with the set norms of industry. This Ph meter is well tested on diverse aspects so as to supply a flawless range to customers. We offer this Ph meter in various specifications to choose from. Our Ph meter is acknowledged among customers for its optimum quality. Features: Reliability Fine finish Dimensional accuracy Other Details: Ph Meter Meter Portable Model Ph-222 Lutron Taiwan Make Digital Ph Meter Portable, Hand Held, Lutron, Taiwan, Model PH-207 Microprocessor Based Range: 0.00 to 14.00 ph, 0 to 1,999 mV, o to 65O C., LCD with Annuciator, ATC Manual Temp, Adj, Max-Min Memory

Send Message
product image
Clinical Chemistry

Acid Phosphatase Diagnostic Reagent (Pack size: 8 x 1 ml) from Accurex. Acid Phosphatase is used in accordance with ISO 14189 to detect acid phosphatase from Clostridium perfringens. Autozyme Acid Phosphate reagent is set for determination of Acid Phosphatase activity based on Kinetic method using a-naphthyl phosphate. In acidic pH of the buffer system, the reagent hydrolyses a-naphthyl phosphate to a-naphthol & phosphate. Accurex has gained considerable expertise in manufacturing & marketing of In-vitro Diagnostic reagents. About Autozyme Acid Phosphate is a reagent set for determination of Acid Phosphatase activity based on Kinetic method using a-naphthyl phosphate Autozyme Acid Phosphate is a single reagent system using one step procedure Autozyme Acid Phosphate can be determined in just 8 minutes at 37 degree C Acid Phosphate can be used on any Spectrophotometer, Discrete semi automated and Automated Analyzer. Programme can be designed for any specific analyzer upon request. Pack Size : 8 x 1 ml Principle In acidic pH of the buffer system, Acid Phosphatase hydrolyses a-naphthyl phosphate to a-naphthol and phosphate. The o-naphthol is then coupled with Diazotized Fast Red TR to form a Diazo dye which has strong absorbance at 405 nm. The increase in absorbance is directly proportional to the level of acid phosphatase in serum. The addition of L-Tartrate inhibits prostatic acid phosphatase but does not inhibit other isoenzymes. The activity of Prostatic Acid Phosphatase is obtained by subtracting the result of Non prostatic Acid phosphatase (Determination with Tartrate) from Total Acid Phosphatase (without tartrate). Quality Control To ensure adequate quality control it is recommended that each batch should include a normal and an abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect ne performance of this test includes proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ AFP Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Alpha-Fetoprotein in human whole blood, serum or plasma. The test is used as an aid for early auxiliary diagnosis and the evaluation of therapeutic efficiency for primary hepatic carcinoma. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ NGAL Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA System for quantitative determination of Neutrophil Gelatinase-Associated Lipocalin (NGAL) concentration in human urine. The test is used as an aid for the diagnosis of kidney injuries. STORAGE AND STABILITY 1. Store the test kit at 4℃~30℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing. 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message

Still searching for
14 ph?