Jaipur
+918529833535

'10 tube positions'

Items tagged with '10 tube positions'

product image
Clinical Chemistry

XL 1000 with the throughput of upto 1040 tests per hour is the ideal instrument for centralizing the complete biochemistry testing load on a single fully automated platform. Increased walk away productivity and less human intervention make it an ideal analyzer for large laboratories. Equipped with all necessary advanced features that one expects from a high end fully automated chemistry analyzer; sample loading through rack system, cooled calibrator and control carousel, low reading volume of 150 µL, diffraction grating with 15 wavelengths from 340 nm to 800 nm and user-friendly software, to optimize and reliably run the daily lab workload. XL 1000 is a "dream come true" workhorse for laboratories with increased workload and the perfect solution. Fully Automatic, Discrete, Patient prioritized, Random Access Clinical Chemistry Analyzer with throughput of 1040 tests/hour 3 Reagent capabilities 147 long life Hard Glass cuvettes Separate Carousel for STAT samples Onboard refrigeration for reagents Extensive database for storing patient data and Q.C. results Primary tube sampling with bar code identification 9 stage laundry for cuvettes wash 150 samples can be loaded at a time through rack system System Discrete, open, automated, random access, patient prioritized, 1/2/3 reagent system DISPENSING OF SAMPLES AND REAGENTS Sample volume: 2-60 µl (0.1 µl step), 70 µl with ISE Reagent volume: 120 µl – 550 µl 3 dispensing probes ( R1, R2/R3) equipped with liquid -level sensor and crash detector Auto-dilution of samples and calibrators Clot detection Samples Serum, urine, plasma, CSF and other Economy Minimum reaction volume: 180 µl Reusable reaction cuvettes Mixing System 2 independent stirrers 3 user selectable mixing speeds Quality Control 4 levels of control material can be used Levey-Jennigs graphs Twin Plot diagrams for monitoring of systematic and random error Reaction unit with wash station 147 reusable hard glass cuvettes Possibility of replacement of individual cuvette Wash station – cuvette rinsing and drying in nine-step procedure Automatic cuvette blank measurement before analysis Sample Autoloader 23 racks 115 sample positions on automatic autoloader Primary tubes 5, 7 and 10 ml, vacuum system tubes Barcode reader for sample identification 2 Reagent trays With 43 cooled position each Barcode reader for reagent identification 20 ml, 50 ml reagent containers, 5 ml tube with adaptor Option to use one reagent for several test simultaneously Stat Tray 45 positions Can be used for blank, controls, STAT samples Software Convenient user interface Connection to LIS Programmable auto-start from sleep mode including automatic daily maintenance Statistical methods of processing results Data export in selected format Measurement Monitoring Colour indication of sample analysis Possibility of monitoring the reaction in real time Reagent volume monitoring Informative reports on ongoing analyzer status

Send Message
product image
Laboratory Usage

Backed ourselves with sound amenities and talented personnel, we have emerged as one of the leading manufacturer and supplier of Manometer U Tube. This product is developed by our professionals utilizing superior grade material in line with international quality norms. The offered product is obtainable in different specifications as per the requirements of the clients. This product is monitored on numerous predefined standards of the industry before its final dispatch to the customers. Features: Dimensionally accurate Precisely engineered Unmatched quality Other Details: Manometer U Tube Type 150-0-150 / 250-0-250 / 500-0-500 (all range Available) Glass U-Tube MANOMETER ANSCHUTZ 100-0-100 mm Supplied on Wooden Stand (w/o Mercury) Yes! I am interested

Send Message
product image
Immunology Analyzer

Fully Automated Chemiluminescence Immunoassay Analyzer Introducing iFlash 1200, a chemiluminescence immunoassay analyzer that offers fully automated immunoassay analysis using Magnetic particle-based Direct Chemiluminescence technology. With a high throughput of up to 120 tests per hour and a first result available in just 13 minutes, iFlash 1200 is one of the fastest and most efficient immunoassay analyzers available on the market. The instrument features continuous STAT sample loading capacity with 16 sample positions, continuous reagents loading capacity with 15 reagent positions, and continuous loading of reaction vessels with a capacity of 500 cuvettes. Additionally, iFlash 1200 uses Acridinium Ester Labeled Direct Chemiluminescence for highly accurate and reliable results, and comes with ready-to-use reagents in convenient 2 x 50 tests pack size for simplified testing. Overall, iFlash 1200 is an innovative and versatile immunoassay analyzer that is perfect for laboratories that require high throughput and rapid turnaround times. iFlash 1200 chemiluminescence immunoassay analyzer Key Features: 1.Continuous loading of reagents with convenient pack size of 2 x 50 tests 2.Continous loading of 500 reaction cuvettes for longer walkaway time 3. 4 step magnetic separation for achieving high precision and quality results 4.Non contact vortex mixer-Highly Efficient technology to prevent carryover & cross contamination Additional information General Information Throughput : upto 120 tests/hour Time to First Results :13 minutes Detection Principle Magnetic particle Based Direct Chemiluminescence Chemiluminescence Label :Acridinium Ester Sample System Sample Position :16 sample position Types of Sample tube :Microcup & blood collecting tubes Sample Volume :5~150μL Reagent System Reagent Position :15 reagent positions with onboard refrigeration Reagent Carousel Temp :2-8 °C Reagent Detection :Reagent Level Tracking Reagent Pack : 2 x 50 tests Reagent Carousel Incubation Capacity :48 reaction vessels Incubation Temperature :37°C+-0.3°C Mixing System :Non-Contact Vortex Mixer Operating Conditions Power Supply :100~240V, 50/60HZ Power Consumption :600VA Temperature :10~30°C Weight :120 Kg Reagents iFlash 1200 reagents iFlash 1200 reagents Pack size 2 x 50 Tests 28 days On board reagent stability 28 days Calibration stability Built in Calibrators for all Parameters

Send Message
product image
Clinical Chemistry

Best Semi Automatic Biochemistry Analyzer AT Smart from Accurex. AT SMART is a Biochemistry/Clinical Analyzer with a user-friendly and the human interface is via touch screen. It measures the optical densities of samples & calculates the sample concentration which are used for biochemical investigation. This Biochemistry Machine operates from near UV to visible range. Semi Auto Analyzer AT SMART is CE certified and has undergone rigors testing before being delivered to customers. About •SMART MAINTENANCE •SMART LIS •SMART INVENTORY MANAGEMENT REDUCED ERRORS: IT allows for the accurate collection of data, automated workflows & minimized waste. SAVES TIME: Patient monitoring can be done in real-time, saves engineers visiting time. BETTER PATIENT EXPERIENCE: A connected laboratory system creates an environment that meets each patient’s needs. INSTRUMENT BREAKDOWN MANAGEMENT: Real-time data helps to monitor instrument performance. ONLINE REACTION CURVES: • Real time reaction curve with special • Flagging gives confidence in patient reports. INTELLECTUAL SOFTWARE: • User friendly Device. • 150 Direct access test keys gives freedom to select parameters easily. • Availability of different assay modes. DRY BATH INCUBATOR: • Dry bath incubator with 12 test tube positions • Mini size with 15 minutes start up time FEATURES: •Remote access & monitoring via Internet •150 test parameters •Built-in thermal printer to print results, enzymatic curves and standard calibration curves •Large graphic display with real time graph display for enzymatic reaction •Touch screen interface with dynamic test access key SPECIFICATIONS: Methodology- • Absorbance • Endpoint with standard, factor, sample blank & diffrential • Two-point (fixed time) and multi point kinetics • Multi standard calibration • Mono or bi-chromatic reading • Turbidimetry Optical System- • Principle: photometry • Range of measurement: 0.0-3.0A • Spectral range selection: Automatic via filter wheel • Filters: 340, 405, 505, 546, 578 and 630 nm plus two free position • Bandwidth:10nm (+/- 2nm) • Light source: Life Long Halogen lamp • Blanking: Automatic • Detector: Silicon Photodiode Photometer- • Peltier regulated 25ºC, 30ºC and 37ºC • Flow cell of 18 µ L • Continuous flow system with peristaltic pump • Programmable Sipping Volume Memory- • 150+ User Defined Test Programs • 1000 test results in instrument memory and unlimited test resultresult storage via cloud • Reagent Blank • 2 Level of QC Quality Control- • Levy-Jennings chart using westgard’s rules • 30 Normal and abnormal QC values for selected test User Interface- • Graphic LCD back Lit 240×64 pixels • Touch Screen input • Data port and cloud connectivity • Type : Graphic thermal printer Power & Dimensions- • Voltage : 220 V • Frequency : 50 Hz • Maximum power : < 150 VA • Maximum relative humidity : 75% • Compact form factor • Weight: < 6kgs Safety Information Precautions • Instrument should be operated only by authorised or trained personnel • For any reasons, unauthorised personnel should not be engaged for servicing or removing the cabinet • Power source should be regulated either by voltage stabilizer or regulated power back up (UPS). If inverter is been used, please ensure there exists a voltage stabilizer • Reagents recommended by the company to be preferably used • Flow cell needs to be rinsed regularly with the company recommended flow cell cleaning solution • User is requested not to use any other pointing devices other than being supplied by company while operating touch screen • The operating environment should be clean and protected from direct sunlight • During the day at the end of the work, it should be ensured that flow cell is always filled with distilled water • During transport / longer duration of shut down, th Direction for Use Please ensure that the power source is properly grounded and voltage between Line and Ground is less than 2V AC – 5V AC. • Please ensure that the instrument is placed on a firm table, clean environment, and sufficient ventilation space. • Switch On the instrument. • Instrument will run its own internal diagnostic routines, to ensure proper working of critical functions. • Allow the instrument to stabilize for 10 minutes. • During the stabilization time, please wash the flow cell with cleaning solution and distilled water for at least two times. • During shut down, ensure that the flow cell is cleaned with flow cell cleaning solution and rinsed thoroughly using distilled water. • For overnight shutdown, please ensure flow cell is filled with distilled water. • Cover the instrument with the given dust cover Other Info GENERAL INFORMATION While installing and setting up the instrument, few safety warnings and general precautions described in the further sections must be observed. A. Power Supply : • Power source should be grounded and have either servo stabilizer or regulated power back up • Power cord should be CE , CSA and UL marked • Voltage : 115 – 230 Volts ± 10% 50 – 60 Hz • Grounding: Make sure that electrical power source is properly grounded.

Send Message
product image
Clinical Chemistry

Product Specification Model Name/Number HumaStar 200 Brand Human Automation Fully Automatic Display Digital Dimensions 69 x 76 x 52 cm (WxDxH) Frequency 50/60 Hz Voltage 220-240 or 110-120 Vac Temperature 16-30 Degree C Throughput Up to 200 t/h throughput Weight 51 kg Reaction volume 210-350 il Wash station 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Languages English, French, Spanish Software (other languages can be added) Humidity < 80 % non-condensing Data External computer required (Pentium IV, 2 GHz Mode Open, random-access, STAT Product Description Product Detail : Unique Random-Access Analyzers for Small to Medium Size Laboratories Unique design Unique software architecture Unique features Analysis Endpoint (bichromatic), Differential endpoint (with sample blank), Fixed time, Kinetic (bichromatic) Multi-standard (up to 8), factor, linear, non linear (cubic-spline, poly-linear and logit-log four parameters) Samples Removable sample tray 60 positions: primary tubes 12–12.5x100 mm and 10 mm cups Optional: sample tray for 20 primary tubes 12–16x100 mm and 20 cups 3.5 ml Sample volume: 2–300 µl Internal barcode reader Automatic pre- and post-dilution Test profiles and replicates Reagents Removable reagent tray 30 reagent / diluent positions 50 and 20 ml bottles, adapter for tubes and cups Reagent volumes: 5–350 µl Refrigeration to ~9 Degree C below ambient (at bottom of bottle) Substrates, Enzymatic, Turbidimetric Reaction Reaction volume: 210–350 µl 80 reusable Bionex® cuvettes 6 mm optical path Heat transfer by air Pipetting Needle shock detector Capacitive liquid level detector Wash station 8-step cuvette wash station Systemic and special washing solution HumaStar 200: 6 dispensing needles Water consumption < 2 l/h (8 ml/test) Optical system 9 discrete wavelengths (340, 405, 505, 546, 578, 600, 650, 700 nm, one free position) Band pass: +/– 5 nm Photometric linearity: 0–2.5 Abs Stability: <1 % drift per day Management 20 GB HDD, 512 MB RAM, CD/R, USB) Windows 7® with .NET framework 4.0 English, French, Spanish OS recommended Core i3TM or dedicated graphic card recommended Minimum 900 dots resolution Designed for touch screen (1280x1024 pixel) LIS: Bi-directional, polling mode, ASTM, ethernet Printouts By patient, single test, complete sample, work sheet, method and QCs, calibration curves, kinetics, continuous printing

Send Message
product image
Hematology

VES MATIC 5 is the next-generation automated module manufactured by Diesse Diagnostica (Italy), a highly advanced, Intelligent, Intuitive & Interactive Graphic user Interface for estimating ESR using EDTA samples. Product Features: Automated instrument for the determination of ESR directly from EDTA vacutainers Faster TAT by loading 216 sample tubes at a time Pediatric samples can be processed in microtainers Reliable results with Temperature correction facility Accurate results by eliminating manual HCT correction in Anaemic samples Real-Time monitoring of samples Detection of Lipemic, Hemolyzed, Coagulated samples Standardization in mixing with Inbuilt Mixer Analyser P. Code Product Name Pack size Vesmatic 5 165941 Next 5K Transponder 1x 5000 Vesmatic 5 165942 Next 10 K Transponder 1x 10000 Display - 19" Full HD (1920x1080) LCD with PCAP Touch Screen Peripheral Control - based on Everex distributed control system with peripheral motor control boards Operating system - Linux Analysis module - 89 Positions for Sample Tubes Sample Loading - up to 18 racks simultaneously Throughput - 190 samples per hour. First result after 28 minutes Walk away mode - Supported Continuous loading - Supported Sample mixing - with multiple 180° rotations of the tubes Collection of analysed samples - reinserted into the original loading rack LIS Connection - Multiple LIS connection protocols are available: ASTM / Proprietary Remote diagnostics - available via Ethernet connection. Printer -Alphanumeric with 58mm-wide thermal paper, 36 characters per line, speed 20 mm/sec. Imaging System - 2 high resolution cameras for sample identification and analysis; 1 standard camera for internal inspection Image processor - Dedicated Quad Core CPU with integrated GPU for real-time HD image processing of samples Temperature range in operation - from +15 to + 35°C; Storage from + 5°C to + 45°C Humidity range - from 20% to 80% without condensation Central unit - Quad core ARM Cortex A-53 CPU ARM Cortex A-53, 16 GB eMMC, 4 GB RAM Interfaces - 2 x RS232C, 2 Host USB, 1 Client USB, Ethernet Protection category - CLASS I Safety standard - EN 61010-1, EN 61010-2-081, EN 61010-2-101 EMC - EN61326-1 Installation category - II Mains voltage - 230VAC@50Hz; US/Canada: 110-120Vac@60Hz Electrical energy consumption - 420VA Fuse block - 2 x 5.0 AT (delayed) (5 x 20 mm) UL Dimensions (mm) - 850 (W) x 750 (H) x 830 (D) Weight - 80 kg

Send Message
product image
Clinical Chemistry

As the workload and test menu increase, simultaneous management of multiple ELISA protocols can become challenging. The LisaXL has been designed with an open architecture to meet various laboratory needs, providing all the tools necessary for hands-free ELISA processing, increasing the reliability and reproducibility, improving throughput, and freeing the laboratory staff from repetitive steps. LisaXL allows running multiple parameters for over 250 samples in a single batch. Equipped with dual probes and dedicated workstations, drastically improve ELISA workflows. LisaXL is a complete walkway system that minimizes manual errors while improving the accuracy and turnaround time for critical tests. LisaXL provides the flexibility to build and run virtually any ELISA assays. Product Features: Lisa XL is a true walk-away system for any laboratory needs. High Throughput with 6 plates, can process up to 576 tests. A dynamic scheduler ensures optimized system usage and turnaround times by processing 6 plates and up to 12 assays in each plate Onboard flexibility with sample capacity up to 272 and 20 interchangeable racks for reagents and samples. Dual probe processing ensures speed and reliability. "Zero" carryover with high-quality disposable tips. Six individually controlled incubators and shakers with variable temperature, time, and speed settings. Efficient washing with super sweep mode ensures minimum residual volume, with up to 6 different wash buffers. Easy to use touchscreen graphic user interface Product Applications: ELISA Physical Specifications 1 Dimensions Length 1375 mm 55" Height 845 mm 33" Width 850 mm 33.5" Weight 195 kgs (Approx) Power Supply Voltage 100 - 240 Volts Frequency 50 / 60Hz Power consumption 700 W General Specifications Assay per plate Up to 12 Number of ELISA plates Up to 6 Sample capacity Up to 272 Sample / Reagent capacity Total 20 racks Single rack holds 16 sample / reagent tubes Double rack holds 6 x 60 ml reagent bottles (can be used interchangeably) Tip / Dilution box Total 11 locations of 96 capacity each (can be used interchangeably) Reader Specifications Reading Range 0.0 - 3.5 O.D Reading Channels 8 Filter wheel 8 positions 405 nm, 450 nm, 492 nm, 620 nm std* 578 nm and 700 nm optional + 2 open Light source Halogen Lamp Reading mode Single, Dual, ORR Reading time < 1 min (for single filter) Linearity Up to 3.0 O.D (450 nm) Washer Specifications Manifold configuration 16 needles - 8 aspiration & 8 dispensing Precision < 5 % at 300 μl Wash cycle Programmable Residual volume < 5 μl / well Soak time Programmable Washer buffer capacity 6 × 2.25 L Waste water container 1 × 20 L Incubator Specifications Number of incubators Up to 6 Temperature range RT + 5°C up to 50°C Temperature stability ± 1°C Incubation time Programmable Time to set temperature < 6 min Shaking 200 to 800 RPM Shaking Method Orbital Pipetting Specifications Number of probes 2 Tips 300 µl / 1000 µl, Auto / Manual selected Multi-dispensing (Reagent) Minimum volume 4 μl Serum dispensing time < 14 min Reagent dispensing time < 5 min Sample mixing Yes (Automatic) Precision Sample & Reagent Sample Dispensing with 300 µl tip: 3% above 10 µl ± 0.5 µl for 10 µl & less Reagent Dispensing with 300 µl tip: 3% for 25 µl & above Reagent Dispensing with 1ml tip: 5% for 75 µl & above" Process Security Liquid level sensing Well fill verification Clot detection Onboard sample identification Onboard reagent identification Strip verification Buffer sensing Alarms Software Operating System Windows 10 (Embedded) LIS interface Bi-directional, Serial / TCPIP USB Port Graphic load interface Graphical work list Data processing Quantitative, Semi-Quantitative & Qualitative Multi password access Ability to archive data Computer (Base configuration considered, higher configuration can be considered for upgrade after testing) Intel Core i3, 4 GB RAM, 1 TB hard disk Monitor 22" Full HD touch screen

Send Message

Still searching for
10 tube positions?