product image
Hematology

Based on Mindray’s continuous innovation in hematology field, BC-5130 is especially tailored to assist diagnostic labs who need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget. As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5130 is a highly user-friendly and innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfill and exceed the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs. Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50 μm in diameter) provides better performance on samples with low PLT. Efficient Only three routine reagents are required. These have 2 years shelf life and also less consumed by BC-5130. Original QC and calibrator are also provided to ensure the hematology analyzer’s traceability and testing quality. WBC 5-Part differentiation,25 reportable parameters & 23 research parameters,3 histograms Whole blood Mode, Capillary whole blood mode & Prediluted Mode Tri-angle Laser Scatter + Chemical dye + Flow cytometry technology Dedicated optical counting channel for Basophil measurement 10.4 inch large TFT touch screen with user-friendly software Large storage capacity: Up to 1,50,000 samples Throughput:60 samples/Hour Compact Two kinds of lyse reagents are located inside of BC-5130, which helps the small labs to save space. BC-5130, the 5-part hematology analyzer offers a great solution for clinical labs, especially for those who have limited space. Its compact foot-print is a result of innovative technology improvements, including miniaturized semi-conductor laser source, highly integrated electronic boards and optimized liquid handling system. BC-5130 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs. Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5130 has higher dilution ratio than other 5-part hematology There’s NLR parameter in each CBC+DIFF result. Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. BC-5130 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well. Technology Compared with traditional helium neon laser or argon laser, semi -conductor laser has smaller size, lower cost and longer life cycle.

Send Message
product image
Instruments

We are the most prominent name engaged in trading and supplying premium quality Thermo Hygrometer Digital With Probe. Offered hygrometer is manufactured by our experienced workforce using outstanding quality materials and latest techniques at our well equipped manufacturing unit. In addition, our offered hygrometer is strictly tested on numerous quality parameters by our quality experts so as to deliver a defect free range from our side. Features: Optimum performance Precision-designed High quality Other Details: Thermo + Hygro + Barometer Model - 3016, Barigo German Make, with Electronic Indicator Product Details: Material Plastic Brand Swastik Accuracy +/- 1 Degree C Display Digital Color White Is It ISO Certified ISO Certified Temperature - 10 to 50 Degree C

Send Message
product image
Laboratory Usage

Product Specification Model VSI-102 Usage Laboratory Display Digital pH Range 0-14 pH Type of PH Meter Table-Top Product Description We are the Leading Supplier of Temp MV Meter. pH: Range: O TO 14 pH Resolution: 0.01 pH Accuracy: 0.01 oG?(Relative) Temp.Comp: Automatic with temp. Probe & manual by keys Buffer Recognition: 4.oo,7.oo,9.20ph(automatic) slope adjustment: 80% to 120% byu derfault 100% Calibration: Manually mV(ORP): Range: 0 To ±1999mV Resolution: 1mV Accuracy: ±1 mV Caliobration: Manual Temperature: Range: 20C to 200C Resolution: o.1C Accuracy: ±0.2% Input Type: Pt 100 Calibratian: Manual Display: 16x2 alphanumeric lcd. Display Format:temp & ph or temp &orp simultaneously auto display of selected buffer Setting: By soft touch keys Storage: 1000 samples with date & time Interfacer: RS-232 centroes & computer Real Time Display: 24 hour mode with date Error Indication PH error, buffer error, orp error Power Supply 230 V±10% AC 50 HZ Digital Output: Serial RS-232 and Parallel Centronics Print Format: All Data and Date wise

Send Message
product image
Diabetes

Product Features: Better precision, CV < 2.5 % Patented CLE technology enables complete elimination of labile glycohemoglobin ensuring accurate HbA1c results. HbA1c test results in 3.5 minutes with HbA2/HbF flagging. Separation of hemoglobin fractions Complete removal of labile fraction up to 10% No interference of HbF up to 10% No interference of lipemia or icterus, can run on non-fasting patient samples HbA1c reportability presence of HbS, HbC, HbD and HbE Compact bench top model User friendly touch screen operation Sampling from multiple sized primary tubes, including microcapillary collection tubes On board QC functions with Levey-Jennings and statistical calculations Unlimited storage of calibration, QC data and chromatograms No sample preparation required Simple reagent and column replacement Automated maintenance RFID reagent identification and tracking Automatic barcode identification of samples NGSP certified Calibrators and Controls IFCC traceable Complete kit with buffers, calibrator and column Product Application: Hba1c Testing Sampler Handler: 10 Position Rack Loader, positive identification by internal barcode reader Sample Type: Whole blood on EDTA K3 or K2 anticoagulant Haemolysate from EDTA whole blood samples Time for Analysis: Throughput approximately 3.5 minutes between samples Interferences: Complete removal (not separation) of labile up to 10% Sampling System: Sample Aspiration Probe coupled with a high precision, Sample Aspiration Volume: 14.5 µl in whole blood, 670 µl in lysate mode. Pump: 2 high pressure syringe pumps Detector Type: UV-Vis Reagent Traceability: RFID Printer: Built- in thermal printer with possibility to connect to external printer

Send Message
product image
Clinical Chemistry

XL 1000 with the throughput of upto 1040 tests per hour is the ideal instrument for centralizing the complete biochemistry testing load on a single fully automated platform. Increased walk away productivity and less human intervention make it an ideal analyzer for large laboratories. Equipped with all necessary advanced features that one expects from a high end fully automated chemistry analyzer; sample loading through rack system, cooled calibrator and control carousel, low reading volume of 150 µL, diffraction grating with 15 wavelengths from 340 nm to 800 nm and user-friendly software, to optimize and reliably run the daily lab workload. XL 1000 is a "dream come true" workhorse for laboratories with increased workload and the perfect solution. Fully Automatic, Discrete, Patient prioritized, Random Access Clinical Chemistry Analyzer with throughput of 1040 tests/hour 3 Reagent capabilities 147 long life Hard Glass cuvettes Separate Carousel for STAT samples Onboard refrigeration for reagents Extensive database for storing patient data and Q.C. results Primary tube sampling with bar code identification 9 stage laundry for cuvettes wash 150 samples can be loaded at a time through rack system System Discrete, open, automated, random access, patient prioritized, 1/2/3 reagent system DISPENSING OF SAMPLES AND REAGENTS Sample volume: 2-60 µl (0.1 µl step), 70 µl with ISE Reagent volume: 120 µl – 550 µl 3 dispensing probes ( R1, R2/R3) equipped with liquid -level sensor and crash detector Auto-dilution of samples and calibrators Clot detection Samples Serum, urine, plasma, CSF and other Economy Minimum reaction volume: 180 µl Reusable reaction cuvettes Mixing System 2 independent stirrers 3 user selectable mixing speeds Quality Control 4 levels of control material can be used Levey-Jennigs graphs Twin Plot diagrams for monitoring of systematic and random error Reaction unit with wash station 147 reusable hard glass cuvettes Possibility of replacement of individual cuvette Wash station – cuvette rinsing and drying in nine-step procedure Automatic cuvette blank measurement before analysis Sample Autoloader 23 racks 115 sample positions on automatic autoloader Primary tubes 5, 7 and 10 ml, vacuum system tubes Barcode reader for sample identification 2 Reagent trays With 43 cooled position each Barcode reader for reagent identification 20 ml, 50 ml reagent containers, 5 ml tube with adaptor Option to use one reagent for several test simultaneously Stat Tray 45 positions Can be used for blank, controls, STAT samples Software Convenient user interface Connection to LIS Programmable auto-start from sleep mode including automatic daily maintenance Statistical methods of processing results Data export in selected format Measurement Monitoring Colour indication of sample analysis Possibility of monitoring the reaction in real time Reagent volume monitoring Informative reports on ongoing analyzer status

Send Message
product image
Rapid Test

Intended Use Dengue NS1 Antigen FP is a rapid solid phase immuno- chromatographic test for the qualitative detection of Dengue NS1 Antigen in human Whole Blood/ Serum/ Plasma. This test is for in vitro diagnostic use only and is intended as an aid in the earlier diagnosis of dengue infection. Salient Features Rapid ,visual test for the qualitative detection of Dengue NS1 Antigen in whole blood/serum/Plasma. Sample can be taken from Finger prick and sample required is 4µl. Based on Sandwich principle. Detection of Dengue in Seronegative stage i.e From Day 1 of fever. Detection of all 4 serotypes of dengue virus. Reliable diagnosis of both primary and secondary infection. 100% Sensitivity & 99.96 % Specificity. Shelf life: 24 month at 2-30 °C Convenient pack Size: 10 Test. Evaluated By Referral Medical college / Hospitals /Research institutes / Labs.

Send Message
product image
Rapid Test

Intended Use Dengue NS1 Antigen self-test is a rapid solid phase immune-chromatographic test for the qualitative detection of Dengue NS1 Ag in human whole blood/serum/plasma. This test is intended to be for home use with self-collected whole blood specimens from individuals aged 18 years or above( or collected by adults for individuals below 18 years of age) as well as for professional use with venous Whole blood/Serum/Plasma samples. This test is for in-vitro diagnostic use only & is designed as an aid in the early diagnosis of dengue infection patients with clinical symptoms. Salient Features Rapid, Visual, Home test for qualitative detection of Dengue NS1 antigen detection in human whole blood/serum/plasma. Finger prick sample can be used. Single test pack. All material to perform the test & its disposal are provided with the kit. Based on Sandwich principle.\ Detection of Dengue in Seronegative stage i.e. from Day 1 of fever. Detection of all 4 serotypes of dengue virus. Reliable diagnosis of both primary and secondary infection. 100% Sensitivity & 100 % Specificity. Shelf life: 30 month at 2-30 °C.

Send Message
product image
Fluorescence Immunoassay Analyzer

The FineCare FIA Meter II plus SE is a top-class fluorescence immunoassay analyzer with a built-in thermal printer, Wifi, internet connectivity, large LCD display for testing common clinical diseases. Description The FineCare FIA Meter II plus is a top-class fluorescence immunoassay analyzer with a built-in thermal printer, Wifi, and internet connectivity, large LCD display for testing common clinical diseases. Technical Specifications Analyses common clinical diseases such as Diabetic & Renal injury Markers, Thyroid function, Fertility, Cardiac Markers, Inflammation Markers, Tumour Markers Built-in Thermal Printer Real-time auto printing Support for external printer Dimension :- 239mm x 278mm x 148mm Weight : 3.3kg Large Display 8” LCD Capacitive touch screen Intuitive user interface Specially designed sampler for a small volume of the specimen. Test Reagent Suitable for whole blood, serum, plasma, and urine Room temperature storage Get results in 3 -15 minutes Test Device Tray Multiple testing modes available Unique quick mode for a large number of samples Keywords large number fluorescence small volume Cardiac Markers Thyroid function large LCD display Inflammation Markers Renal injury Markers internet connectivity common clinical diseases LCD Capacitive touch screen Intuitive user Built-in Thermal Printer Immunoassay Analyzer, Finecare Analyzer, TSH, HbA1c, Point of care , immunoassay, Clia Analyses common clinical diseases such as Diabetic & Renal injury Markers, Thyroid function, Fertility, Cardiac Markers, Inflammation Markers, Tumour Markers