Jaipur
+918529833535

'1 5 kgs'

Items tagged with '1 5 kgs'

product image
Hematology

Based on Mindray’s continuous innovation in hematology field, BC-5130 is especially tailored to assist diagnostic labs who need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget. As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5130 is a highly user-friendly and innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfill and exceed the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs. Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50 μm in diameter) provides better performance on samples with low PLT. Efficient Only three routine reagents are required. These have 2 years shelf life and also less consumed by BC-5130. Original QC and calibrator are also provided to ensure the hematology analyzer’s traceability and testing quality. WBC 5-Part differentiation,25 reportable parameters & 23 research parameters,3 histograms Whole blood Mode, Capillary whole blood mode & Prediluted Mode Tri-angle Laser Scatter + Chemical dye + Flow cytometry technology Dedicated optical counting channel for Basophil measurement 10.4 inch large TFT touch screen with user-friendly software Large storage capacity: Up to 1,50,000 samples Throughput:60 samples/Hour Compact Two kinds of lyse reagents are located inside of BC-5130, which helps the small labs to save space. BC-5130, the 5-part hematology analyzer offers a great solution for clinical labs, especially for those who have limited space. Its compact foot-print is a result of innovative technology improvements, including miniaturized semi-conductor laser source, highly integrated electronic boards and optimized liquid handling system. BC-5130 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs. Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5130 has higher dilution ratio than other 5-part hematology There’s NLR parameter in each CBC+DIFF result. Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. BC-5130 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well. Technology Compared with traditional helium neon laser or argon laser, semi -conductor laser has smaller size, lower cost and longer life cycle.

Send Message
product image
Laboratory Usage

Soil moisture meter TDR 150 Portable soil moisture meter allows you to obtain readings on the go at the press of a button. Variable rod length options provide soil moisture measurements at your ideal root zone. With new enhancements, the TDR 150 provides significant improvements in performance and measurement accuracy for optimal turf and soil environments. Increased accuracy of soil moisture (Volumetric Water Content) Measures EC (Electrical Conductivity) Measures Turf Surface Temperature Option to add on Bluetooth and GPS Data logger records approximately 50,000 measurements Industry exclusive backlit display Ergonomic handle Data collected with USB flash drive No PC interface needed Powered by AA lithium batteries Ideal for measuring containers on benches Optional IR Temp sensor to measure canopy TDR 150 SPECIFICATIONS Measurement Principle: Time - domain measurement methods Measurement Units: Percent Volumetric Water Content (VWC) Resolution: 0.1% VWC Accuracy: +- 3.0% VWC with Electrical Conductivity (EC) < 2 mS/cm Range: 0% to saturation (Saturation up to about 50% volumetric water depending on soil type) Battery/Life: 4 AA lithium batteries; approximately 100,000 readings without backlight Data Logger: 50,000 measurements EC Range: 0 to 5 mS/cm, Resolution: 0.01 mS/cm, Accuracy: +/- 0.1 mS/cm Temperature Range: -30°C to 60°C, Resolution: 0.1°, Accuracy: +/- 1°C

Send Message
product image
BP Apparatus

Product Details: Model DR-A1 Application Industrial Range 1.3000 to 1.7000 Material PVC Color White With enriched industrial experience, we have been able to offer a wide spectrum of Refractometer Digital 0-85 %. This product is tested by our experts for ensuring its flawlessness before supplying to customers end. Offered product is manufactured from better quality material and cutting-edge techniques in compliance with the set norms of the industry. The offered product is provided in different specifications as per the variegated demand of customers. Features: Application specific design Maintenance free Trouble free performance Other Details: Model DR-A1 Range 1.3000 to 1.7000 with built in light Abbe Refractometer Digital Model WAY - 2S Additional Information: Item Code: WAY-2S

Send Message
product image
Glucometer

The GLUCOCARD Vital is everything a blood glucose meter should be - fast, accurate and easy to use. A small 0.5 µL sample size in our GO-based test strip platform gives accurate results in as little as 7 seconds. This auto coded meter has a 250-test memory, records 14- and 30-day averaging and is downloadable. Sample volume: 0.5 μL Test time: 7 seconds Meter range: 20-600 mg/dL Results: Plasma referenced Calibration: Auto coding Display: LCD Memory: 250 tests with time & date stamp Averaging: 14- and 30-day averaging Downloadable: Yes

Send Message
product image
Clinical Chemistry

Find the Best Semi Automatic Biochemistry Analyzer from Accurex. Buy Acculab At 112 Plus (Semi Auto Biochemistry Analyzer) which is the best Biochemistry Machine with numerous features like Filter Check, Self-check operation for optical filters, Checks the absorbance of each of the 7 filters & free position, Ensures that all the filters are in good working condition. This Biochemistry Analyzer has Improved ergonomic touch screen display, ensures strain free viewing with End point, kinetic, fixed time & absorbance mode. FILTER CHECK • Self-check operation for optical filters. • Checks the absorbance of each of the 7 filters & free position. • Ensures that all the filters are in good working condition. WORKLIST • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. LAMP SAVING • Lamp saving option available ensuring long lamp life. • The lamp can be turned off in case of sporadic sample workload ALARMS • Audio alarm is sounded when results are higher (S) or lower (L) than reference range ensuring that all abnormal samples are flagged for further review. • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design Methodology: End point, kinetic, fixed time & absorbance Calibration: Single standard/multi-point linear/multi-point non-linear Programmable channels: 112 Memory: 3200 results Quality control: Comprehensive QC software with L-J graph Light source:Quartz-Halogen lamp 12V / 20W Photometric range: 0.0000 to 3.0000 Abs, Resolution : 0.0001 Abs : Drift : 0.002 Abs/hour Wavelength range: 7 standard filters: 340, 405, 492, 510, 546, 578, 630 nm & 1 free optional position ; Half Bandwidth < 8 nm : Stray light : < 1.0 % at 340 nm, Stainless steel body with quartz window; Optical path 10 mm Flowcell: Stainless steel body with quartz window; Optical path 10 mm Measuring volume: 32 μl Programmable aspiration volume:: 500-2000 μl Temperature control: Peltier elements : 25°C, 30°C & 37°C ±0.1°C Input: Ergonomic LCD touch screen display Printer: Built-in high speed thermal printer Interface: RS-232 serial port Dimension / Weight: 450 x 360 x 140 mm / 11.5 kgs Operating environment: Temperature: 15-30°C ; Humidity: 20-80 % Power requirement: AC 110-220 V ±10%, 50/60 Hz Safety Information • The position of the LCD display has been designed to reduce cervical (neck muscle) strain during continual use. • The aerial view display design makes it possible to view the screen from multiple perspectives, (standing or sitting, with equal clarity). Direction for Use • A unique facility by which a worklist can be prepared for every sample ID. • Printouts can be taken by sample ID or test parameters. • Print by ID : Ensures that no test is left out for a particular ID. • Print by Test : Ensures that all reagents / working solutions are prepared in correct volumes preventing wastage. • The system flags any test which is missed out for a particular ID, ensuring all assay panel is completed. Other Info • Improved ergonomic touch screen display, ensures strain free viewing • End point, kinetic, fixed time & absorbance mode • Single & bichromatic measurement • Memory : 3200 results • 112 programmable channels • Calibration modes – 1 standard / multi-point linear / multi-point non-linear • Easy-access maintenance chamber ensures efficient uptime management • Real-time reaction curve display • Anti-vibration & anti-disturbance optical system ensures highly accurate results • Option of 7 filters (340 – 630 nm) & 1 free position • Comprehensive quality control program with L-J graph • Lamp saving feature to prolong lamp life • Audible / visual alarm available • Easy-tear printer design

Send Message
product image
Hemoglobin Meter

Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Buy Accurex H12 Hemoglobin Test Strips Online – for better result & accuracy. These Hemoglobin strips are used with URIT Hemoglobin Meter, for the quantitative measurement of total hemoglobin in capillary and venous whole blood. These hb strips are to be used by health care professionals only, not to be used for patient self-testing. Accurex HB Test Strips come with a pack size of 50 strips. The Accrues test strip utilizes Dry Chemistry Colorimeter Method (Azido methemoglobin Method). Meter’s optical detectors automatically measure the change in the membrane Operation Principle: The test strip utilizes Dry Chemistry Colorimeter Method (Azido methaemoglobin Method). When a drop of whole blood is applied to the test spot on the strip, blood immediately disperses within the membrane, contacting the reagent. The meter’s optical detectors avtomatically measure the change in membrane reflectance. The intensity of reflectance is inversely proportional to the hemoglobin concentration. Blood Sample Collection: Fresh or EDTA-anticoagulated capillary or venous whole blood may be used. If an EDTA – treated sample is refrigeratted to come to the room temperature before testing. EDTA treated blood samples should be mixed using end to and inversions at least 8 times prior to use, and should be tested within 24nours Do not use the haemolytic sample anticogulants other than EDTA are not recommended for use. Caution: 1. Same as all diagnostic tests, hemoglobin test results should be evaluated with the specific patient’s condition. Any results demonstrating the inconsistency with the patient’s clinical status should be repeated or supplemented with additional test data. 2. Do not touch the test membrane by hand 3. H12 Hemoglobin Test Strips are one-off product, do not use again Storage & Preparation: 1.H12 Hemoglobin Test Strips should be stored at O C-30 C dry and dark places, 2 C – B C is the best storage environment emperatures recommended. Keep away from direct sunlight and heat, must not be frozen, If the container was stored in refrigerated before first use, please don’t take it back into the refrigerator again after first use. 2. H12 Hemoglobin Test Strips are ready to use. No additional preparation is required 3. Enclosed desiccants with lest strip. Remove only those strips needed for testing. The remaining lest strips should be resealed in their onginal container and used up in 3 months after first use. Do not use lest strips and throw away alter expiry date. 4. Use the strip immediately once taking it out af the container, otherwise the result will be incorrect 5. Do not fold or cut the test strip. 6. Used lest strips cannot be used again, dispose them as normal medical waste Direction for Use Operating Instructions: 1. URIT Hemoglobin Meter, H12 Hemoglobin Test Strip, Lancing Device, and disposable blood taking needle. 2. Test steps: 1) Turn the meter on and input the Code Card. Check the Code Card displaying on the meter to ensure it to match the Code Card printed on the lest strip container. Otherwise, the result is incorrect. 2) Massage the patient’s finger from the knuckle up to the tip to stimulate blood flow. Clean the sample area with alcohol and wipe it dry with a sterile gauze pad. 3) Insert the lest strip into the strip holder with the notched end in first and the hole facing up. 4) Puncture the skin on the lower side of fingertip with blood collection needle, and remove 13-15 TIL of whole biood with capillary or other micro blood collection apparatus. While waiting for the instrument to display the blood drop symbol, quickly add the drops to the test hole on the reagent sheet. Please make sure that the blood drop volume can completely cover the test hole but not overflow the test hole. 5) The meter starts the test automatically after the blood sample disperses Once the lest is in process do nol disturb or move the meter or test strip, or press any key. The test result will display within 12 seconds. Qualtiy Control Procedure: Use only H12 Hemoglobin Test Strip with QC substance to perform QC. The range of QC substance is the numerical range indicated on the label of the QCsubstance or test strips. When to do a QCtest: 1. Whenever you suspect that the meter or test strips are not working properly. 2. If your hemoglobin test results are not consistent with how you feel. Other Info Limitations of test Method: H12 Hemoglobin Test Strip is only suitable for testing fresh or whole capillary blood or whole venous blood containing EDTA anticoagulants. Do not use serum, plasma or arterial blood

Send Message
product image
Rapid Test

Buy AccuTest HIV – 1/2 Ab Rapid Card Test (50 Tests) Online from Accurex. This Rapid HIV test is a visual, solid phase immunochromatographic assay for qualitative in-vitro diagnostic detection of antibodies against HIV-1 and HIV-2 in human serum/plasma. This HIV test may be used as an aid in diagnosis of HIV infection. In the HIV blood test – A reactive result should be confirmed by supplemental testing as part of a validated HIV testing algorithm. INTENDED USE: AccuTest HIV – 1/2 Ab test is a visual, solid phase immunochromatographic assay for qualitative in-vitro diagnostic detection of antibodies against HIV-1 and HIV-2 in human serum/plasma. The product may be used as an aid in diagnosis of HIV infection. A reactive result should be confirmed by supplemental testing as part of a validated HIV testing algorithm. INTRODUCTION: The Human Immunodeficiency Virus (HIV) is a retrovirus that infects cells of the immune system, destroying or impairing their function. The most advanced stage of HIV infection is Acquired Immunodeficiency Syndrome (AIDS). The general method of detecting infection with HIV is to observe the presence of antibodies to the virus by an EIA method followed by confirmation with any confirmation method. AccuTest HIV – 1/2 Ab is a simple, visual qualitative test that detects antibodies in human serum/plasma. The test is based on immunochromatography and can give a result within 15 minutes. PRINCIPLE: AccuTest HIV – 1/2 Ab employs chromatographic lateral flow device in a cassette format. Colloidal gold conjugated recombinant antigens (Au-Ag) corresponding to HIV-1 (gp120 + gp41) and HIV-2 (gp-36) are dry-immobilized at the end of nitrocellulose membrane strip. HIV-1 & HIV-2 antigens are bound at the Test Zone (1 & 2) respectively. Goat Anti-Mouse IgG antibodies are bound at the Control Zone(C). When the sample is added, it migrates by capillary diffusion rehydrating the gold conjugate. If there are HIV-1 or HIV-2 antibodies in sample, they will bind with the gold conjugated antigens forming particles. These particles will continue to migrate along the strip until the Test Zone (1 or 2) where they are captured by the HIV-1 or HIV-2 antigens generating a visible purple line. If the specimen contains antibodies to HIV-1, the specimen will bind to the 1 test line and produce line. If specimen contains antibodies to HIV2, the specimen will bind to the 2 test line. If there are no HIV-1 or HIV-2 antibodies in sample, no purple line is formed in the Test Zone. The gold conjugate will continue to migrate alone until it is captured in the Control Zone (C) by the Goat Anti Mouse IgG antibodies aggregating in a purple line, which indicates that the migration of liquid has been successful. The control line must be present for the test to be valid. PRECAUTIONS: 1. For best results, adhere to instructions provided. 2. All specimens should be handled as potentially infectious. 3. The test device is sensitive to humidity as well as heat. 4. Do not use beyond expiration date. 5. Do not use test kit if pouch is damaged or seal is broken. 6. Use test device immediately after removing from the pouch. 7. The components (test device and assay diluents) in this kit have been quality control tested as a standard batch unit. Do not mix components from different lot numbers. 8. The AccuTest HIV – 1/2 Ab Test devices should be stored at 4 to 30 °C. Do not expose the kit to temperature over 30 °C. 9. Specimen with extremely high concentrations of red blood cells, fibrin should be recentrifuged before use. 10. AccuTest HIV – 1/2 Ab Test Device (Serum/Plasma) is for in vitro diagnostic use only. 11. AccuTest HIV – 1/2 Ab Test Device (Serum/Plasma) will only indicate the presence of antibodies to HIV-1/2 in the specimen and should not be used as the sole criteria for the diagnosis of HIV-1, HIV-2, and/or HIV-1 subtype O infection. 12. For confirmation of reactive test results, specimens should undergo further testing using different assays, such as rapid diagnostic tests, EIA and/or Western blotting in accordance with a validated HIV testing algorithm. 13. As with all diagnostic tests, all results must be interpreted together with other clinical information available to the physician. 14. Results should not be used to determine the serotype of HIV infections TEST PROCEDURE: 1. Allow the test device, buffer and specimen to reach room temperature (15-30 °C) prior to testing. 2. Remove the test device from the foil pouch and use the test device as soon as possible (within one hour). 3. Place the device on a flat, dry surface. Label with specimen ID. 4. Holding the sample dropper vertically above the test disk, slowly transfer 1 drop (10µl) of sample in to the sample well, then add 2 drops of assay diluent (about 75 µl) and start the timer. 5. As the test begins to work, you will see purple color moving across the result Window in the center of the Test Disk. 6. Wait for the colored lines to appear. Interpret test results at 15 to 20 minutes. Do not interpret test result after 20 minutes. STORAGE AND STABILITY Store as packaged in the sealed pouch at 4-30 °C (storage in refrigerator is permitted). Do not store in the freezer. Protect the test kit from humidly. The test device is stable until the expiration date printed on the test kit and/or sealed test device pouch. Do not use beyond the expiration date. The test device must remain in the sealed pouch until use.

Send Message
product image
Rapid Test

Buy Dengue NS1 Antigen test (Pack of 5 test) from Accurex. This NS1 Antigen Rapid test contains: A Test device in aluminum pouch with a desiccant, Disposable dropper & Pack Insert. Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. Dengue NS1 Antigen kit is for professional use and only for the initial screening test & reactive samples should be confirmed by a supplemental assay such as nucleic acid test & other immunological assays. EXPLANATION OF THE TEST Dengue NS1 antigen test utilizes the human serum / plasma followed by solid-phase immuno-chromatographic technology for the qualitative detection of dengue virus NS1 antigen. The membrane strip of the kit contains pre-coated anti-dengue NS1 monoclonal antibody on the test band region (T), and goat anti-mouse IgG is pre-coated on the control band region (C). During testing, if the sample containing dengue NS1 Ag, the complex of the antibody-dengueNS1 Ag-gold conjugate moves laterally on the membrane by capillary action. In this case, the colored band will appear on the membrane in test line (T). Control line (C) should always appear if the test procedure is performed properly Safety Information 1. For in-vitro diagnostic use only. Do not re-use the test device. 2. The instruction must be followed exactly to get accurate results. 3. Anyone performing an assay with this product must be trained in its use and must be experienced in laboratory procedures. 4. Do not eat or smoke while handling specimens. 5. Wear protective gloves while handling specimens. Wash hands thoroughly afterwards. 6. Avoid splashing or aerosol formation. 7. Clean up spills thoroughly using an appropriate disinfectant. 8. Decontaminate and dispose of all specimens, reaction waste, in a biohazard container. 9. Do not mix and interchange different specimen. 10. The presence of humidity may decrease the stability of the tests. Thus, carry out the test immediately after removing the device from the foil pouch. 11. Do not use it beyond the expiration date. Direction for Use 1. Place all specimens, test device and solution. Allow them to room temperature prior to testing (15~30 min.) 2. Please perform the test immediately after removing the device from the foil pouch. 3. With a disposable dropper, load 2-3 drops (50 to 75µl) of specimen into the sample well (S) in the test device. 4. Interpret the test results between 15~20 minutes. Do not read the results after 20 minutes. Other Info 1) Dengue NS1 Antigen test should be stored between 4~30 ºC 2) Expiration date of this kit is 24 months after its manufacture date. LIMITATIONS OF THE TEST Dengue NS1 antigen test is designed for primary screening test of dengue virus NS1 antigen. Although this can provide fast and easy way to get a result, the testing do not completely exclude the possibility of false positive or negative result caused by various factor. So, refer to the result of the kit, please make a final decision with clinical manifestation, other test results and doctor’s view collectively.

Send Message
product image
Glycohemoglobin Analysis

Xpress A1c strips are used for a testing of quantitative determination of glycated hemoglobin(HBA1c) in human whole blood. It is used to monitor metabolic control in diabetic patients. it helps in diagnosis of the diabetes or pre-diabetes in adults. Buy Xpress A1c strips online (Pack of 25 Strips) – the best a1c test strips from Point of Care (POC) Range of Accurex HbA1c strips works as both a pipette and measuring element. A Blood drop of 8uL is needed for measurement. This blood is drawn into the cavity by capillary action. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes. The Xpress A1c strips works as both a pipette and measuring element. A Blood drop of 8uL is needed for measurement. This blood is drawn into the cavity by capillary action. The Xpress A1c strips then needs to be inserted into Xpress A1c meter for hemoglobin measurement, The Xpress A1c meter measures the absorbance of whole blood at Hb isosbestic point. Xpress A1c meter uses two wavelengths of light to calculate Hemoglobin level, user level calibration is not required. How to use: Step 1: Wash hands using soap and warm water. Rinse and dry thoroughly. Step 2: Turn on the meter by pressing-releasing the power button. Step 3: Remove an Xpress A1c strip from the vial. Step 4: Prick a finger to obtain a blood sample. Step 5: Touch and hold the drop of blood to the pointed edge of the Xpress A1c strip. The blood is drawn into the Xpress A1c strip by capillary action Step 6: Once the blood fills the Xpress A1c strip chamber. Insert the Xpress A1c strip into the Xpress A1c meter. Step 7: Your Hemoglobin result will appear on the display window. Step 8: Remove the Xpress A1c strip from the meter and discard it. The meter will automatically turn off or long-press the power button to turn off. The Xpress A1c strips are used to quantitatively measure the concentration of HbA1C in whole blood, suitable for the self-monitoring of HbA1C for diabetes patients. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes. is used to quantitatively measure the concentration of HbA1C in whole blood, suitable for the self-monitoring of HbA1C for diabetes patients. It helps users to understand their diabetes control status or to monitor their risk of developing diabetes.Features: Sample Type: Whole Blood/EDTA Blood/Capillary Blood Measuring Range: 0 to 25 g/dl Temperature: 0°C-50°C Storage Temperature: Room Temperature Expiry: Long Expiry(min 02 yrs) Pack Size: 25 Test/Vial LIMITATION AND WARNING: 1. This product is used for In Vitro Diagnostics only, not for in vivo use. 2. This product should not be used past the expiration date. 3. If there is evidence of microbial contamination or browning, discard the vial. 4. This product is not intended to be used as an HbA1c standard. 5. Preservatives contained in the control, rinse with water if splash into the mouth or eyes, and seek medical help as soon as possible. 6. Potential biological risk. Direction for Use This product should be run in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. (1) Dissolution: Open the cap of the vial, and then add 2 drops of Buffer A. Close the cap, and slightly shake the vial until the powder dissolved completely. And please shake it well before using it. (2) Testing in accordance with instructions accompanying BioHermes Glycohemoglobin Test Kit and Glycohemoglobin Analyzer. Please refer to the B Storage: 1. This product will be stable for 24 months when stored tightly capped at 2-8℃. 2. After dissolved, the product can be stable for 8 hours at 10-30℃, or 5 days at 2-8℃. Do not freeze it. COMPOSITION: This product is prepared from human blood and contains normal hemoglobin, preservatives and stabilizers. The control is provided in lyophilized powder form for increased stability. The kit contains two levels of control, level 1 is with yellow cap, and level 2 is with green cap.

Send Message

Still searching for
1 5 kgs?