Jaipur
+918529833535

'0 999 ppm'

Items tagged with '0 999 ppm'

product image
Instruments

A high-end ventilator featured with 1080P HD wide screen, combines an intuitive customized UI with powerful assistive tools and modules. Operate with Ease In the modern busy clinical environment, ease of use is a fundamental requirement for all medical devices. With this in mind, the new SV800/SV600 ventilators enable clinicians to set and deliver ventilation therapies quickly and easily via the intelligent ergonomic design and flat user interface. Intelligent Decision Making Ventilation modes and decision-supporting tools like SBT are developed on the basis of clinical needs and professional guidelines to help free up medical personnel’s time on device operation and focus more on their patients. p68-s4 Extensive ventilation therapy and decision support tools Smart ventilation solution: AMV TM + IntelliCycle TM Emergency solution: CPRV TM Sequential treatment regimen: Non-invasive ventilation & high flow oxygen therapy Dual channel auxiliary pressure measurements Lung protection kit Expandable Capabilities Securing your devices future is reliant on being able to expand your devices capabilities by interacting or integrating new features and technologies. The SV800/SV600 ventilators allow just this. Thanks to latest software and platform it is utilizing, your device is ready to embrace new technological advancement with ease. p68-s0-0 Integrated neonatal module with tidal volume setting down to 2ml Plug & Play modules , including SpO₂, mainstream or sidestream CO₂ Backup air supply in case of central air supply failure and during intra-hospital transport Seamlessly connected to the hospitals clinical information system via the Mindray BeneLink and eGateway modules, or directly via the HL7 p68-s5 Brand - Mindray Model Name/Number SV800 Patient Age Group Adult, Pediatrics & Neonatal Tidal Volume For adult : 100 to 4000 ml, For Pediatric 20 to 300 ml, For neonatal : 2 to 100 ml Ventilation Mode V-A/C, P-A/C, V-SIMV,P-SIMV, Duolevel, CPAP, PSV, APRV, PRVC, NIV, PRVC-SIMV, AMV, CPRV, PSV-S/T, nCPAP, VS Respiratory Rate For adult/pediactrics : 1 to 100/min,for neonate :-1 to 150/min Additional Details Weight 45 kg ventilator + 16.3 kg trolley Plateu (%) OFF, 5% to 60% Peak airway pressure 0 to 100 cm H2O SIMV Rate ,Cycle/min 1 to 60 rpm Mounting type Trolley I:E Ratio 1:10 to 4:1 Touch screen 18.5 inch color active matrix TFT touch screen RSBI 0-9999/1/(L-min) Features Customizing the UI Graphic guidelines Single level menu design Dual channel auxiliary pressure monitore

Send Message
product image
Laboratory Usage

Product Specification Model VSI-102 Usage Laboratory Display Digital pH Range 0-14 pH Type of PH Meter Table-Top Product Description We are the Leading Supplier of Temp MV Meter. pH: Range: O TO 14 pH Resolution: 0.01 pH Accuracy: 0.01 oG?(Relative) Temp.Comp: Automatic with temp. Probe & manual by keys Buffer Recognition: 4.oo,7.oo,9.20ph(automatic) slope adjustment: 80% to 120% byu derfault 100% Calibration: Manually mV(ORP): Range: 0 To ±1999mV Resolution: 1mV Accuracy: ±1 mV Caliobration: Manual Temperature: Range: 20C to 200C Resolution: o.1C Accuracy: ±0.2% Input Type: Pt 100 Calibratian: Manual Display: 16x2 alphanumeric lcd. Display Format:temp & ph or temp &orp simultaneously auto display of selected buffer Setting: By soft touch keys Storage: 1000 samples with date & time Interfacer: RS-232 centroes & computer Real Time Display: 24 hour mode with date Error Indication PH error, buffer error, orp error Power Supply 230 V±10% AC 50 HZ Digital Output: Serial RS-232 and Parallel Centronics Print Format: All Data and Date wise

Send Message
product image
Digital Spectrophotometer

Product Details: Application Laboratory Accuracy 0.001 g Position Hand Held Make Japan, Brix Material Steel, Rubber Type Portable We are the leading of Coolant Hand Refractometers. Salinity Refractometer, ERMA, Japan Make, Range: 0-28%, Range: 0-100% Hand Refractometer Model D, for urine, Serum / Protein, ERMA JAPAN make Model : D Refractometer for battery/ coolants, ERMA Japan Gem Refractometer Digital portable refractometer imported Make Brix : 0-45%, Refractive Index Range : 1.3330 to 1.7000 Digital portable refractometer imported Make Brix : 0-95%, Refractive Index Range : 1.4098 to 1.5318 nD, Salinity : 0-30% U.S.A Salinity meter, Digital (Table Model), 3 1/2 Digit LED Display with Salinity Cell & Other Accessories Digital specific gravity salinity meter Temperature Meter, Model DSG - 10 Range : Specific Gravity : 1.000 - 1.030, Salinity (PPT) : 5 ppt to 40 ppt, Temp : 0ºC - 100ºC Digital salinity TDS Temperature Meter, Model: HDS 1024, Imported Make Range : Salinity : 0.00 - 5.00 % Salt, TDS : 0-999 ppm mg/L, Temperature : 0ºC to 100ºC

Send Message
product image
Biochemistry Analyzer

Yumizen CA40 Semi-automated Clinical Chemistry Analyzer: Yumizen CA40 is a semi-automated Clinical Chemistry analyzer with facility to perform Chemistry, Immunoturbidimetry and Coagulation Tests (PT & APTT). It is an ideal solution for small laboratories with the facility to perform a wide range of biochemical tests. Specification:- Semi-automated Clinical Chemistry analyzer with coagulation tests capacity (PT & APTT) 8 incubation positions for chemistry tests and 5 positions for coagulation tests 8-inch colored touch screen display Tri-level Quality Control with Levey-Jennings chart 6 filters with additional 2 open positions Show less

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ S100β Rapid Quantitative Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for quantitative determination of S100β in human serum, plasma or whole blood. The test is used as an aid to the assessment of the level of cerebral injury. STORAGE AND STABILITY 1. Store the test kit at 4 ~ 30 ℃ up to the expiration date printed on package. 2. If removed from refrigerator, allow the test kit for 30 minutes to return to room temperature before testing 3. Do not remove the Test Cartridge from the pouch until use. The Test Cartridge should be used within 1 hour once opened.

Send Message
product image
immunoassayReagents

INTENDED USE The Finecare™ 2019-nCoV RBD Antibody Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for qualitative and semi-quantitative detection of spike receptor-binding domain (RBD) antibodies of novel coronaviruses (2019-nCoV) in human fingerstick whole blood, venipuncture whole blood, serum or plasma specimen. The 2019-nCoV RBD antibodies are protective antibody produced by the human body after inoculation with 2019-nCoV vaccine or infection with 2019-nCoV. The test is intended as an aid to assess the adaptive humoral immune response to the 2019-nCoV RBD protein. STORAGE AND STABILITY 1. Store at 4~30°C in the sealed pouch up to the expiration date printed on the package. Do not freeze. 2. The test device should be used within 1 hour after taking out from the foil envelope. 3. Keep away from sunlight, moisture and heat. 4. Kit contents are stable until the expiration date printed on the outer box.

Send Message
product image
Immunoassay Reagents

INTENDED USE The Finecare™ 2019-nCoV lgM/lgG Test is a fluorescence immunoassay used along with Finecare™ FIA Meters for qualitative detection of IgG and IgM antibodies of novel coronaviruses (2019-nCoV) in human whole blood, serum and plasma specimen. Clinically, the test is to be used as an aid in the diagnosis of coronavirus infection disease (COVID-19), which is caused by 2019-nCoV. The test provides preliminary test results. Negative results cannot exclude the possibility of 2019-nCoV infection and they cannot be used as the sole basis for treatment or other management decision. STORAGE AND STABILITY 1. Store at 4-30°C in the sealed pouch up to the expiration date printed on the package. Do not freeze. 2. The test device should be used within 1 hour after taking out from the foil envelope. 3. Keep away from sunlight, moisture and heat. 4. Kit contents are stable until the expiration date printed on the outer box.

Send Message

Still searching for
0 999 ppm?